650 Amps, Southern States, CAP 145 CAP-145, 146 KV, 31.5 KA

Power Asset Recovery Corp | N. Canton, OH
Seller: Power Asset Recovery Corp
Location: N. Canton, OH
Mfr: Southern States
Model: CAP 145

1200 Amps, ABB, 121 PM 40 20 121PM40-20, SF-6 Breaker, 40 KA, 121 kV, stock #S126G

Power Asset Recovery Corp | N. Canton, OH
Seller: Power Asset Recovery Corp
Location: N. Canton, OH
Mfr: Abb
Model: 121 PM 40 20

1200 Amps, ABB, SACE HA 3 /S 15 5001200 SACE HA3/S-15-500-1200, 15kV, SF6 Breaker, 120V Control Voltage, (9 available)

RS Breakers And Controls | Mississauga, ON
Seller: RS Breakers And Controls
Location: Mississauga, ON
Mfr: Abb
Model: SACE HA 3 /S 15 5001200

1200 Amps, Federal Pacific, SFA 17 SFA-17, 15kV, SF6 Breaker, 125VDC Control Voltage, (6 available)

RS Breakers And Controls | Mississauga, ON
Seller: RS Breakers And Controls
Location: Mississauga, ON
Mfr: Federal Pacific
Model: SFA 17

1200 Amps, General Electric, DT 1 145 F1 SF6 DT1-145 F1 SF6, breaker, 145 KV, 1999

Veracity Asset Services Inc | Uxbridge, ON
Seller: Veracity Asset Services Inc
Location: Uxbridge, ON
Mfr: General Electric
Model: DT 1 145 F1 SF6
Year: 1999
1999 GE DT1-145 F1 SF6 Breaker 145kV 1200AClick REQUEST QUOTE anywhere you see it on our site to receive a quote, with Pricing and, directly to your email!!* All s, and s are correct to the best of our knowledge. Interested buyers should verify before purchasing.

Get email updates for newly added Outdoor Gas Circuit Breakers

Outdoor Gas Circuit Breakers (also known as SF₆ circuit breakers) use sulfur hexafluoride gas as an insulating and arc-quenching medium to interrupt high-voltage circuits outdoors. Commonly used in utility substations and power transmission, these breakers offer reliable overcurrent protection, withstand harsh weather, and support stable, efficient power distribution.

1200 Amps, M.g., FG 2 FG-2, 15kV, SF6 Breaker, 120VAC Control Voltage, (5 available)

RS Breakers And Controls | Mississauga, ON
Seller: RS Breakers And Controls
Location: Mississauga, ON
Mfr: M.g.
Model: FG 2

1200 Amps, Siemens, 155 KV Type SDV 7 Outdoor Gas Circuit Breake 15.5 KV Type SDV7 Outdoor Gas Circuit Breaker w/ Type VSS-17006 Interrupter, 2024, New

Veracity Asset Services Inc | Uxbridge, ON
Seller: Veracity Asset Services Inc
Location: Uxbridge, ON
Mfr: Siemens
Model: 155 KV TYPE SDV 7 OUTDOOR GAS CIRCUIT BREAKE
Year: 2024
NEW Siemens 15.5kV 1200Amp Type SDV7 Breaker with Type VSS-17006 InterrupterClick REQUEST QUOTE anywhere you see it on our site to receive a quote, with Pricing and, directly to your email!!* All s, and s are correct to the best of our knowledge. Interested buyers should verify before purchasing.

1200 Amps, Siemens, service factor 6 /SPS 2 38402 SF6/SPS2-38-40-2, 38 KV, 40 KAIC

Power Asset Recovery Corp | N. Canton, OH
Seller: Power Asset Recovery Corp
Location: N. Canton, OH
Mfr: Siemens
Model: SF 6 /SPS 2 38402

2000 Amps, Areva, DTI 725 F 1 4 DTI-725-F1K4, High-Voltage SF6 Dead-Tank Circuit Breaker, 72.5 KV, 2008

Veracity Asset Services Inc | Uxbridge, ON
Seller: Veracity Asset Services Inc
Location: Uxbridge, ON
Mfr: Areva
Model: DTI 725 F 1 4
Year: 2008
2008 AREVA 72.5 kV SF Dead-Tank Circuit Breaker rated 40 kA interrupting and 2000 A continuous current, designed for high-reliability transmission and sub-transmission applications. s a spring-charged FK3 operating mechanism, 3-cycle interrupting time, and robust 350 kV impulse insulation rating. Built for harsh ...more

2000 Amps, General Electric, DT 1 145 DT1-145, SF6 breaker, 145 KV, 40kA short-circuit, 650kV BIL

844XFORMER | Manchester, NH
Seller: 844XFORMER
Location: Manchester, NH
Mfr: General Electric
Model: DT 1 145
We are a third-generation, family-owned sales agency with over 50 years of experience serving the electric power industry. With deep technical knowledge of transformers and related equipment, we provide expert advice to help customers make informed purchasing decisions., We maintain access to a broad network of ...more

2000 Amps, General Electric, DT 1 362 F3 DT1-362 F3, SF6, breaker, 362 KV, 63kA short circuit, 1300kV BIL

844XFORMER | Manchester, NH
Seller: 844XFORMER
Location: Manchester, NH
Mfr: General Electric
Model: DT 1 362 F3
We are a third-generation, family-owned sales agency with over 50 years of experience serving the electric power industry. With deep technical knowledge of transformers and related equipment, we provide expert advice to help customers make informed purchasing decisions., We maintain access to a broad network of ...more

2000 Amps, General Electric Hitachi, HBV 121 40000 HBV-121-40000, 121 KV, SF6 breakers, 1993 (x3)

Veracity Asset Services Inc | Uxbridge, ON
Seller: Veracity Asset Services Inc
Location: Uxbridge, ON
Mfr: General Electric
Model: HBV 121 40000
Year: 1993
GE-Hitachi HBV-121-40000 121kV 2000A SF6 Dead-tank Circuit Breakers.Three breakers, all identical and of the same age. All were taken out of service recently since the plant ceased operations.The breakers are located in South America.Shipping to any place can be arranged at customer request.There are test reports ...more

2000 Amps, Siemens, 3 AP 2 3AP2, 500 KV, live tank circuit breaker, FI-550 kV w/ SF6+CF4 gas

Rising Edge Group | Regina, SK
Seller: Rising Edge Group
Location: Calgary, AB
Mfr: Siemens
Model: 3 AP 2
Year: 2024
QTY 1 - Siemens New Surplus 3P 500KV 2000AMP Live Tank Breaker, See, technical data, Technical data according to, IEC 62271-100, Brand, SIEMENS ENERGY, Type, live Tank, Model, 3AP2 FI-550 kV, Mechanical Construction Data, Number of poles, 3, Number of circuit breaker operating mechanism, 3, Interrupter units per pole ...more

2000 Amps, Siemens, 245 V service factor breaker 245kV service factor breaker, new

IC Spares | Los Angeles, CA
Seller: IC Spares
Location: Los Angeles, CA
Mfr: Siemens
Model: 245 V SF BREAKER
Siemens, SPS2-245-40-2, kV: 245, Amps: 2000, New.

2000 Amps, Siemens, service factor 6 / SPS 2 145402 SF6 / SPS2-145-40-2, gas insulated cuitcuit breaker, 145 KV

Bullock Breakers | Annandale, MN
Seller: Bullock Breakers
Location: Annandale, MN
Mfr: Siemens
Model: SF 6 / SPS 2 145402
Year: 2002
Siemens SF6 Gas Insulated Circuit Breaker SPS2-145-40-2 145KV 2000A 60Hz Total Weight w/ Gas: 7200lbs Number of Cycles: 60 Voltage Range Factor(K): 1.0 Short Circuit Current: 40000A Out of Phase Current: 10000A Full Wave Impulse Withstand: 650kV Interrupting Time: 3 Cycles Overvoltage Factor: 2.0 Line Charging: 160A ...more

2000 Amps, Siemens, SPS 2 725402 SPS2-72.5-40-2, power circuit breaker, SF6, 72.5 KV

Energia Solar Cachanilla | Mexicali, Mexico
Seller: Energia Solar Cachanilla
Location: mexicali, baja california, Mexico
Mfr: Siemens
Model: SPS 2 725402
Year: 2014
Power circuit breaker, sulfur hexafluoride, type SPS2-72.5-40-2, 2000 A, 72.5 KV.

2000 Amps, Siemens, SPS 2 725402 SPS2-72.5-40-2, 72.5 kV, SF-6 Breaker

Power Asset Recovery Corp | N. Canton, OH
Seller: Power Asset Recovery Corp
Location: N. Canton, OH
Mfr: Siemens
Model: SPS 2 725402

2000 Amps, Siemens, SPS 145 40 2000 SPS-145-40-2000, 145 KV, 125 VDC close/trip/motor

Belyea Company Inc | Easton, PA
Seller: Belyea Company Inc
Location: Easton, PA
Mfr: Siemens
Model: SPS 145 40 2000
Year: 1996
CB-17631:, ONE (1) 2000 AMP SIEMENS SF6 CIRCUIT BREAKER, TYPE SPS-145-40-2000, 145 KV, 1.0 K VOLTAGE RANGE FACTOR, 3.0 CYCLE INTERRUPT, 40 KA SHORT CIRCUIT, 60 HERTZ, 10 KA OUT OF PHASE CURRENT, 650 KV BIL, 125 VDC CLOSE & TRIP, 125 VDC MOTOR, 6 X 2000:5 MRCT'S C-800 TYPE BCM, SPS-SE4 MECHANISM, 7200 LBS. ...more

2000 Amps, Westinghouse, service factor 6 SF6, 145 KV, 40 KAIC S-46

Power Asset Recovery Corp | N. Canton, OH
Seller: Power Asset Recovery Corp
Location: N. Canton, OH
Mfr: Westinghouse
Model: SF 6

3000 Amps, ABB, 145 PMG 80 30 145 PMG 80-30, 145 KV, 80 KA

Power Asset Recovery Corp | N. Canton, OH
Seller: Power Asset Recovery Corp
Location: N. Canton, OH
Mfr: Abb
Model: 145 PMG 80 30

3000 Amps, ABB, HPL 362 / 31 B2 HPL362/31B2, 362 KV, live tank SF6

Belyea Company Inc | Easton, PA
Seller: Belyea Company Inc
Location: Easton, PA
Mfr: Abb
Model: HPL 362 / 31 B2
Year: 1988
BELYEA STOCK# CB-17844, 3000 AMP ABB SF6 LIVE TANK CIRCUIT BREAKER, TYPE HPL362/31B2, 362000 V, 1300KV BIL, 3 POLE, 50 KA SHORT CIRCUIT, 20 CYCLE INTERRUPTING TIME, OPERATING DEVICE 205A101-01 BLG1002, MAX. GAS PRESSURE 116 PSI ABS, FILLING PRESSURE AT 20 DEG. C 73 PSI ABS, SIGNAL/BLOCKING AT 20 DEG. C 65/62 PSI ABS ...more

3000 Amps, Alstom, DT 1 725FKF1 SF6 Circuit breaker 72.5 kv DT1-72.5FK-F1 SF6 Circuit breaker 72.5 kv, 40 ka Unused

NSV Energy, LLC | Canton, GA
Seller: NSV Energy, LLC
Location: Canton, GA
Mfr: Alstom
Model: DT 1 725FKF1 SF6 CIRCUIT BREAKER 72.5 KV
Stock #CB59, UNUSED SF6 CIRCUIT BREAKER ALSTOM Model: DT1-72.5FK-F1, Serial: 139342-010-A, DEAD TANK, 72.5KV, 3PH, 3000AMP CONT, 40KA IC, 3 CYCLE, 350KV BIL, CONT VOLT 125VDC, MECH VOLT 125VDC/120VAC, (2) 2000:5 BCT, C800 @ 1200:5 PER BUSH, TRF=3, FK3-1/131 SPRING MECHANISM, THROW OVER SCHEME, YEAR BUILT 11/2012, MADE ...more

3000 Amps, General Electric, service factor 6 SF6, Gas Insulated Circuit Breaker DT1-72.5FK-F1, 72.5 KV

Bullock Breakers | Annandale, MN
Seller: Bullock Breakers
Location: Annandale, MN
Mfr: General Electric
Model: SF 6
Year: 2017
GE SF6 Gas Insulated Dead Tank Circuit Breaker DT1-72.5FK-F1 72.5KV 3000A 60Hz Number of Cycles: 132 Overvoltage Factor: 2.0 Voltage Factor: 1.5 Line Charging: 100A Isolated Bank: 630A Back to Back: 360A Inrush Peak: 25kA Inrush Frequency: 3360Hz Out of Phase Switching: 10kA Rated Interrupting Time: 3.0 Cycles ...more

3000 Amps, HVB, service factor 6 SF6, Gas Insulated Circuit Breaker HS145 B, 145 KV

Bullock Breakers | Annandale, MN
Seller: Bullock Breakers
Location: Annandale, MN
Mfr: Hvb
Model: SF 6
Year: 2006
HVB SF6 Gas Insulated Circuit Breaker HS145 B 145KV 3000A 50/60Hz Number of Cycles: 274 Voltage Range Factor: 1.0K Short Circuit Current: 4.0kA Percent DC Component: 55% Interrupting Time: 3 Cycles Full Wave Lighting Impulse Withstand Voltage: -Terminal to Ground, Circuit Breaker Closed: 650kV -Terminal to Terminal ...more

3000 Amps, HVB, service factor 6 SF6, gas insulated circuit breaker, HS145 B, 145 KV

Bullock Breakers | Annandale, MN
Seller: Bullock Breakers
Location: Annandale, MN
Mfr: Hvb
Model: SF 6
Year: 2007
HVB SF6 Gas Insulated Circuit Breaker HS145 B 145KV 3000A 50/60Hz Number of Cycles: 99 Voltage Range Factor(K): 1.0 Short Circuit Current: 4.0kA Percent DC Component: 55% Interrupting Time: 3 Cycles Full Wave Lighting Impulse Withstand Voltage: -Terminal to Ground, Circuit Breaker Closed: 650kV -Terminal to Terminal ...more

3000 Amps, Siemens, service factor 6 SF6, Gas Insulated Circuit Breaker SPS-145-40-3000, 145 KV

Bullock Breakers | Annandale, MN
Seller: Bullock Breakers
Location: Annandale, MN
Mfr: Siemens
Model: SF 6
Year: 1997
Siemens SF6 Gas Insulated Circuit Breaker SPS-145-40-3000 145KV 3000A 60Hz Number of Cycles: 113 Rated Voltage Range Factor: 1.0(K) Rated Short Circuit Current: 40000A Rated Out of Phase Current: 10000A Full Wave Impulse Withstand: 650kV Rated Interrupting Time: 3.0 Cycles Rated Current Switching: -Overall Factor: 2.0 ...more

3000 Amps, Siemens, SPS 2 145 633 SPS2-145-63-3, SF6 circuit breaker, 14 KV

Belyea Company Inc | Easton, PA
Seller: Belyea Company Inc
Location: Easton, PA
Mfr: Siemens
Model: SPS 2 145 633
Year: 2009
CB-19648, ONE (1) 3000A Siemens SF-6 Circuit Breaker, 145 kV Rated Max Volts, SPS2-145-63-3, Rated Voltage Range Factor 1.0 (K), 63 KA Rated Short Circuit Current, Rated Out of Phase Current 15.8 KA, 60 Hertz, 3 Cycle Interrupt, 650 kV BIL, Weight of breaker with Gas 8000 lbs., Weight of SF6 Gas 128 lbs., 87 psig ...more

4000 Amps, Siemens, service factor 6 / SPS 2 72.5402 SF6 / SPS2-72.5-40-2, 73 KV, 40 KAIC

Power Asset Recovery Corp | N. Canton, OH
Seller: Power Asset Recovery Corp
Location: N. Canton, OH
Mfr: Siemens
Model: SF 6 / SPS 2 72.5402

2000 Amp, ABB, HPL 145 / 25 A1 HPL 145/25 A1, 123 KV, 125 VDC C & T, LIVE TANK, BLG1002 MECH

Belyea Company Inc | Easton, PA
Seller: Belyea Company Inc
Location: Easton, PA
Mfr: Abb
Model: HPL 145 / 25 A1
Year: 1990
CB-17938:, ONE (1) 2000 AMP ABB SF6 CIRCUIT BREAKER, LIVE TANK, TYPE HPL 145/25A1, 60 HERTZ, 123 KV MAX. VOLTAGE, 550 KV BIL, 60 KA SHORT CIRCUIT, 2.3 CYCLE INTERRUPT, BLG1002 SPRING CHARGED MECHANISM, MFG. 1990, 116 PSI MAX. GAS PRESSURE, 73 PSI FILLING PRESSURE, 65/62 PSI SIGNAL/BLOCKING PRESSURE, 125 VDC CLOSE, 125 ...more

1600 Amp, ALSTOM, DT 1 725 F1 DT1-72.5 F1, 69 KV, 125 VDC CLOSE & TRIP, CRR4-5 MECH.

Belyea Company Inc | Easton, PA
Seller: Belyea Company Inc
Location: Easton, PA
Mfr: Alstom
Model: DT 1 725 F1
Year: 2002
CB-18327:, ONE (1) 1600 AMP ALSTOM SF6 CIRCUIT BREAKER, TYPE DT1-72.5 F1, 72.5 KV, 40 KA SHORT CIRCUIT, 350 KV BIL, 3 CYCLE INTERRUPT, RATED K FACTOR 1, 60 HERTZ, 98.6 PSIG OPERATING PRESSURE, 48 LBS. OF GAS, CRR4-5 SPRING CHARGED MECHANISM, -30 DEG. C TO +40 DEG. C TEMPERATURE RANGE, 125 VDC CLOSE & TRIP, 120 VAC ...more

Merlin Gerin, outdoor gas switch, 7000 v recloser switch 27kv recloser switch

Fourniture Electrique Laurentienne | Saint-Jérôme, QC
Seller: Fourniture Electrique Laurentienne
Location: Saint-Jérôme, QC
Mfr: Merlin Gerin
Model: 7000 V RECLOSER SWITCH

2000 Amp, MITSUBISHI, 70 SFMT 40 E 70-SFMT-40E, 72.5 KV, 2007, BM-1 MECH., 125 VDC C & T

Belyea Company Inc | Easton, PA
Seller: Belyea Company Inc
Location: Easton, PA
Mfr: Mitsubishi
Model: 70 SFMT 40 E
Year: 2007
CB-18601:, ONE (1) 2000 AMP MITSUBISHI SF6 CIRCUIT BREAKER, TYPE 70-SFMT-40E, 72.5 KV MAXIMUM VOLTAGE, 60 HERTZ, 1.0 RANGE FACTOR K, 40 KA SHORT CIRCUIT, 3 CYCLE INTERRUPT, 350 KV BIL, 125 VDC CLOSE & TRIP, 125 VDC MOTOR, 240 VAC HEATER, 71 PSIG NORMAL PRESSURE, 64 PSIG ALARM PRESSURE, 57 PSIG MINIMUM PRESSURE ...more