For Sale by Turbine Diagnostic Services Inc
Surplus Record Dealer Since 2014
Ron Rubrecht
813-60...> Show Seller's Phone Number 813-601-7100 Let the seller know you found their listing on Surplus Record!
Description
The following is a technical
description of the Viking Power plant design:
The heart of the peaking power plant is the Viking Gas Turbines, one model KG2-3C and three model KG2-3A machines currently upgraded to KG2-3C technology and firing status. These radial flow gas turbines with Ideal generators were originally designed as emergency standby generators. These four gas turbine generators have been inspected, repaired and upgraded to allow for continued operation at higher firing temperatures. These units are being constructed into a modular peaking power plant totaling 5-6.5 megawatts, depending on the site conditions. The only requirements for the site is the access of power lines, access of fuel and a water supply to feed
the inlet air water fogging system (BACT).
The site consists of four turbine containers and inlet containers, an
electrical services container, and a control room container.
These four gas turbines are packaged into 20' shipping containers. The containers are lined with sound attenuation insulation. The lube oil coolers are installed into the packages and provide ventilation as well as cooling for the package. The air inlet filter house, silencer, and inlet duct work is mounted and supported on the top of the turbine container. The inlet duct elbow is fitted with inlet air water fogging nozzles from a system supplied by MEE Industries. This inlet water fogging system will reduce the inlet temperature, reducing NOX emissions, and increasing power output. The exhaust ducts, silencer, and stack exit the container and turns upward supported off of the end of the shipping container.
The units are black start capable. The control system will run off of a 24vdc battery bank for power with a small UPS system to supply power to the HMI computers. The machines use air stored in two tanks at 475 psig for air starting of the units along with the air driven start up oil and fuel pumps.
The Ideal generators output power at 480vac voltage level and cable tray carries the generator leads to the breakers in the switchgear container.
The units are synchronized to a 480vac power bus located inside the
switchgear container. This bus is back fed from the distribution size
transformer and the transmission size transformer from the transmission lines. Power signals are supplied to multifunction relays located in the breaker panels for generator protection. The multifunction relays provide operational output information to the control system in the control container via a modbus communications link. The Viking Power distribution step-up transformers are be monitored by multi-function relays located a cabinet in the electrical container (no transformers provided).
The control container contains the turbine control systems with two PLCs per panel. On each panel will have auto synchronizing relays for the two machines controlled from that panel. The panel also contains provisions to conduct manual synchronizing. The turbine control systems and a balance of plant PLC interfaces with two HMI (Human Machine Interface) computers set up with graphics to allow for the site control. One HMI is for control and the other HMI is for software development and backup. These HMI units communicate with a historian used to collect sequence of events and performance data from the data highway. The entire plant will be controlled from the HMI station and via a modem connection to remote locations with proper password protection.
The units are currently set up for operation on liquid fuel, however, they can be modified to burn natural gas.
description of the Viking Power plant design:
The heart of the peaking power plant is the Viking Gas Turbines, one model KG2-3C and three model KG2-3A machines currently upgraded to KG2-3C technology and firing status. These radial flow gas turbines with Ideal generators were originally designed as emergency standby generators. These four gas turbine generators have been inspected, repaired and upgraded to allow for continued operation at higher firing temperatures. These units are being constructed into a modular peaking power plant totaling 5-6.5 megawatts, depending on the site conditions. The only requirements for the site is the access of power lines, access of fuel and a water supply to feed
the inlet air water fogging system (BACT).
The site consists of four turbine containers and inlet containers, an
electrical services container, and a control room container.
These four gas turbines are packaged into 20' shipping containers. The containers are lined with sound attenuation insulation. The lube oil coolers are installed into the packages and provide ventilation as well as cooling for the package. The air inlet filter house, silencer, and inlet duct work is mounted and supported on the top of the turbine container. The inlet duct elbow is fitted with inlet air water fogging nozzles from a system supplied by MEE Industries. This inlet water fogging system will reduce the inlet temperature, reducing NOX emissions, and increasing power output. The exhaust ducts, silencer, and stack exit the container and turns upward supported off of the end of the shipping container.
The units are black start capable. The control system will run off of a 24vdc battery bank for power with a small UPS system to supply power to the HMI computers. The machines use air stored in two tanks at 475 psig for air starting of the units along with the air driven start up oil and fuel pumps.
The Ideal generators output power at 480vac voltage level and cable tray carries the generator leads to the breakers in the switchgear container.
The units are synchronized to a 480vac power bus located inside the
switchgear container. This bus is back fed from the distribution size
transformer and the transmission size transformer from the transmission lines. Power signals are supplied to multifunction relays located in the breaker panels for generator protection. The multifunction relays provide operational output information to the control system in the control container via a modbus communications link. The Viking Power distribution step-up transformers are be monitored by multi-function relays located a cabinet in the electrical container (no transformers provided).
The control container contains the turbine control systems with two PLCs per panel. On each panel will have auto synchronizing relays for the two machines controlled from that panel. The panel also contains provisions to conduct manual synchronizing. The turbine control systems and a balance of plant PLC interfaces with two HMI (Human Machine Interface) computers set up with graphics to allow for the site control. One HMI is for control and the other HMI is for software development and backup. These HMI units communicate with a historian used to collect sequence of events and performance data from the data highway. The entire plant will be controlled from the HMI station and via a modem connection to remote locations with proper password protection.
The units are currently set up for operation on liquid fuel, however, they can be modified to burn natural gas.
Get Your Price from Turbine Diagnostic Services Inc!
Buyers Who Viewed This Listing Also Viewed …
1479 KW Siemens #STC-SV-08-8-B, 2-Stage Centrifugal Gas Compressor, 435324 cfm, 135 PSI, Flender gearbox, lube oil, sound attenuated enclosure, frame mount, air circulation & ctrls, 2014 (2 available)
Category: Gas Turbine Generators
Seller: Aaron Equipment Co
Location: Schaumburg, IL
Mfr: Siemens
Model: STC-SV-08-8-B
used siemens stc-sv (08-8)-b two-stage centrifugal gas compressors 1479 kw, 12,327 m/h, 9 bar max. rated power 1479 kw. rated capacity 12,327 m3/hour. 0.2 barg inlet pressure. 3.7 discharge pressure 9 bar (135 psi) maximum allowable discharge pressure. driven via a flender tx45/6c1gearbox by an 1800kw motor, gas ...more
JUST ADDED!
1200 KW Saturn 20 #GE1-SA-MA, Gas Turbine Generator Set, 392 Hrs
Category: Gas Turbine Generators
Seller: Quantum Technology
Location: Shippensburg, PA
Mfr: Saturn
Model: GE1-SA-MA
900KW-1200KW Saturn 20 Gas Turbine Generator Set GE1-SA-MA 392Hrs, 882 Starts 30-Day Warranty & Functional Guarantee, Shop with confidence! We guarantee everything we sell to be fully functional. Your purchase is backed by our 30-day warranty—if it doesn’t work as described, we’ll make it right. ...more
3000 KW Solar #Centaur-40, 13800 Volts, 60 Hz., 2 turbine generator systems, (2 available)
Category: Gas Turbine Generators
Seller: Integrated Energy Networks Llc
Location: Dade City, FL
Mfr: Solar
Model: CENTAUR-40
Year: 2014
800 KW Solar #10-T1201, enclosure, 60 Hz, 277/480 Volts, 9182-11984 hours, 2013 (2 available)
Category: Gas Turbine Generators
Seller: Industrial Motor Power Corp
Location: Encino, CA
Mfr: Solar
Model: 10-T1201
3750 KW Allison #501-KB, gas turbine generator, NG/LF, single shaft, 14680 RPM turbine, 3600 RPM reduced output (2 available)
Category: Gas Turbine Generators
Seller: Collicutt Energy Services
Location: Red Deer, AB
Mfr: Allison
Model: 501-KB
(for the 501-KB model)Type Single-shaft, axial flow, industrial gas turbine Power Output ~3,750 kW (5,000 HP) mechanical shaft power Generator Power Output ~3.5 to 4.0 MW (electrical, when used as genset) Fuel Type Natural Gas, Liquid Fuels (diesel, kerosene) Compressor 14-stage axial compressor Combustor Annular ...more