For Sale by Atlantic Power & Equipment
Description
29 BRAND-NEW CUMMINS DATA CENTER–GRADE GENERATOR SETS AVAILABLE
Immediate Availability | Worldwide Shipping
Due to a major international project delay, 29 brand-new Cummins data center–quality generator sets are now available for immediate sale.
These units were originally ordered in November of last year for deployment in Ghana. That project has been rescheduled for August 2026, creating a rare opportunity to acquire top-tier, mission critical power equipment with no lead time.
BUILT DIFFERENT — TRUE DATA CENTER–GRADE POWER
These are Cummins’ highest-quality data center models, not standard standby generators.
✔ Designed for Prime Power — capable of running continuously for months
✔ Larger Engines & Heavy-Duty Construction — significantly more robust than standard C2000 models
✔ Factory-Ordered Upgraded Cooling Package — cooling capacity exceeds standard factory specifications
✔ Optimized for High Ambient Temperatures & Continuous Load
✔ Tier 2 Industrial Diesel
✔ Ideal for Data Centers, Mining, Oil & Gas, Utilities, and Industrial Power
PRICING — VOLUME DISCOUNTS AVAILABLE
All units are brand new and unused
🚚 Shipping included anywhere in the lower 48 states
🌍 Worldwide shipping available
CONFIGURATION & OPTIONS
- Open-on-rails units
- Cummins does not manufacture enclosures for these models; however, we work with two trusted third-party enclosure providers
- Base fuel tanks available
- Supplemental fuel tanks available up to 18,000 gallons
- Documentation attached for a NEW 2500 kW modelshowing available enclosure options
MODEL COMPARISON
DATA CENTER–GRADE MODEL (FOR SALE):
https://www.atlanticpowerequip.com/product-page/dqkab-cummins-2000kw-diesel-tier-2-industrial-generator
STANDARD STANDBY MODEL (FOR COMPARISON ONLY):
https://www.atlanticpowerequip.com/product-page/c2000d6e-cummins-2000kw-diesel-centum-series-tier-2-industrial-generator
MARKET REALITY — EXTREME SUPPLY CONSTRAINTS
⚠️ Worldwide generator shortages persist
- Cummins lead times:~12-14 months
- Caterpillar lead times:22–26 months for units above 1500 kW
Immediate availability at this scale is exceptionally rare. Once these units are sold, replacements will likely take years, not months.
ACT IMMEDIATELY
If your organization—or someone in your network—needs high-capacity, data center-grade power without waiting years, this is a rare acquisition opportunity.
First come, first served. Quantities are limited.
Please reach out promptly for availability, technical details, or to reserve unitsuNModel: DQKAB
Frequency: 60
Fuel type: Diesel
KW rating: 2000 standby
825 prime
Emissions level: EPA NSPS Stationary Emergency Tier 2
Exhaust emission data sheet: EDS-1065
Exhaust emission compliance sheet: EPA-1099
Sound performance data sheet:
Cooling performance data sheet: MCP-158
Prototype test summary data sheet: PTS-267
Standard set-mounted radiator cooling outline: 0500-4392
Optional set-mounted radiator cooling outline: 0500-4780
Optional heat exchanger cooling outline:
Optional remote radiator cooling outline: 0500-4393
Fuel consumption Standby Prime Continuous
kW (kVA) kW (kVA) kW (kVA)
Ratings 2000 (2500) 1825 (2281)
Load 1/4 1/2 3/4 Full 1/4 1/2 3/4 Full Full
US gph 46.5 82 107.3 141.3 43.4 75.1 100.6 124.1
L/hr 176 311 407 535 164 285 381 470
Engine manufacturer Cummins Inc.
Engine model QSK60-G6 NR2
Configuration Cast iron, V 16 cylinder
Aspiration Turbocharged and low temperature aftercooled
Gross engine power output, kWm (bhp) 2179 (2922) 1975 (2647)
BMEP at set rated load, kPa (psi) 2420 (350) 2185 (316)
Bore, mm (in) 159 (6.25)
Stroke, mm (in) 190 (7.48)
Rated speed, rpm 1800
Piston speed, m/s (ft/min) 11.4 (2244)
Compression ratio 14.5:1
Lube oil capacity, L (qt) 334 (304)
Overspeed limit, rpm 2100 ±50
Regenerative power, kW 168
Fuel flow
Maximum fuel flow, L/hr (US gph) 946 (250)
Maximum fuel inlet restriction, kPa (in Hg) 30 (9.0)
Maximum fuel inlet temperature, °C (°F) 71 (160)
Generator set data sheet
Our energy working for you.™
www.cumminspower.com
2011 Cummins Power Generation Inc. All rights reserved. Cummins Power Generation and Cummins are registered trademarks of Cummins Inc.
“Our energy working for you.” is a trademark of Cummins Power Generation. Specifications are subject to change without notice.
D-3336h (10/11)
Combustion air, m3/min (scfm) 178 (6295) 159 (5615)
Maximum air cleaner restriction, kPa (in H2
O) 6.2 (25)
Alternator cooling air, m3/min (cfm) 204 (7300)
Exhaust
Exhaust flow at set rated load, m3/min (cfm) 436 (15385) 385 (13580)
Exhaust temperature, °C (°F) 488 (900) 466 (870)
Maximum back pressure, kPa (in H2
O) 6.8 (27)
Standard set-mounted radiator cooling
Ambient design, °C ( °F) 40 (104)
Fan load, kWm
(HP) 57 (77)
Coolant capacity (with radiator), L (US gal) 492 (130)
Cooling system air flow, m3/min (scfm) 1922 (67870)
Total heat rejection, MJ/min (Btu/min) 99.5 (94395) 91.0 (86382)
Maximum cooling air flow static restriction, kPa (in H2
O) 0.12 (0.5)
Maximum fuel return line restriction kPa (in Hg) 30 (9.0)
Optional set-mounted radiator cooling
Ambient design, °C (°F) 50 (122)
Fan load, kWm
(HP) 57 (77)
Coolant capacity (with radiator), L (US gal) 617 (163)
Cooling system air flow, m3/min (scfm) 2795 (98700)
Total heat rejection, MJ/min (Btu/min) 99.5 (94395) 91 (86382)
Maximum cooling air flow static restriction, kPa (in H2
O) 0.12 (0.5)
Maximum fuel return line restriction, kPa (in Hg) 30 (9.0)
Optional heat exchanger cooling
Set coolant capacity, L (US gal)
Heat rejected, jacket water circuit, MJ/min (Btu/min)
Heat rejected, aftercooler circuit, MJ/min (Btu/min)
Heat rejected, fuel circuit, MJ/min (Btu/min)
Total heat radiated to room, MJ/min (Btu/min)
Maximum raw water pressure, jacket water circuit, kPa (psi)
Maximum raw water pressure, aftercooler circuit, kPa (psi)
Maximum raw water pressure, fuel circuit, kPa (psi)
Maximum raw water flow, jacket water circuit, L/min (US gal/min)
Maximum raw water flow, aftercooler circuit, L/min (US gal/min)
Maximum raw water flow, fuel circuit, L/min (US gal/min)
Minimum raw water flow at 27 °C (80 °F) inlet temp, jacket water
circuit, L/min (US gal/min)
Minimum raw water flow at 27 °C (80 °F) inlet temp, aftercooler circuit,
L/min (US gal/min)
Minimum raw water flow at 27 °C (80 °F) inlet temp, fuel circuit, L/min
(US gal/min)
Raw water delta P at min flow, jacket water circuit, kPa (psi)
Raw water delta P at min flow, aftercooler circuit, kPa (psi)
Raw water delta P at min flow, fuel circuit, kPa (psi)
Maximum jacket water outlet temp, °C (°F)
Maximum aftercooler inlet temp, °C (°F)
Maximum aftercooler inlet temp at 25 °C (77 °F) ambient, °C ( °F)
Maximum fuel return line restriction, kPa (in Hg)
2011 Cummins Power Generation Inc. All rights reserved. Cummins Power Generation and Cummins are registered trademarks of Cummins Inc.
“Our energy working for you.” is a trademark of Cummins Power Generation. Specifications are subject to change without notice.
D-3336h (10/11)
Optional remote radiator cooling1 Standby
rating
Prime
rating
Continuous
rating
Set coolant capacity, L (USg gal)
Max flow rate at max friction head, jacket water circuit, L/min
(US gal/min) 1902 (502)
Max flow rate at max friction head, aftercooler circuit, L/min
(US gal/min) 606 (160)
Heat rejected, jacket water circuit, MJ/min (Btu/min) 46.9 (44526) 44.1 (41824)
Heat rejected, aftercooler circuit, MJ/min (Btu/min) 33.9 (32156) 30.4 (28887)
Heat rejected, fuel circuit, MJ/min (Btu/min)
Total heat radiated to room, MJ/min (Btu/min) 18.7 (17713) 16.5 (15671)
Maximum friction head, jacket water circuit, kPa (psi) 69 (10)
Maximum friction head, aftercooler circuit, kPa (psi) 48 (7)
Maximum static head, jacket water circuit, m (ft) 18 (60)
Maximum static head, aftercooler circuit, m (ft) 18 (60)
Maximum jacket water outlet temp, °C (°F) 104 (220) 100 (212)
Maximum aftercooler inlet temp at 25 °C (77 °F) ambient, °C (°F) 49 (120)
Maximum aftercooler inlet temp, °C (°F) 66 (150)
Maximum fuel flow, L/hr (US gph)
Maximum fuel return line restriction, kPa (in Hg) 30 (9.0)
Weights2
Unit dry weight kgs (lbs) 14628 (32249)
Unit wet weight kgs (lbs) 15155 (33410)
Notes:
1 For non-standard remote installations contact your local Cummins Power Generation representative.
2 Weights represent a set with standard features. See outline drawing for weights of other configurations.
Derating factors
Standby
Engine power available up to 447 m (1466 ft) at ambient temperatures up to 40 °C (104 °F). From 447 m
(1466 ft) up to 2001 m (6562 ft) engine derates at 5.1% per 305 m (1000 ft) for 40 °C (104 °F). Above
these elevations, derate an additional 5.8% per 305 m (1000 ft). For temperatures from 40 °C (104 °F) to
50 °C (122 °F) derate 14.6%. For temperatures above 50 °C (122 °F) derate 29% per 10 °C (50 °F).
Prime
Engine power available up to 447 m (1466 ft) at ambient temperatures up to 40 °C (104 °F). From 447 m
(1466 ft) up to 2001 m (6562 ft) engine derates at 5.1% per 305 m (1000 ft) for 40 °C (104 °F). Above
these elevations, derate an additional 5.8% per 305 m (1000 ft). For temperatures from 40 °C (104 °F) to
50 °C (122 °F) derate 14.6%. For temperatures above 50 °C (122 °F) derate 29% per 10 °C (50 °F).
Continuous
Ratings definitions
Emergency standby power
(ESP):
Limited-time running power
(LTP):
Prime power (PRP):
Base load (continuous)
power (COP):
Applicable for supplying power
to varying electrical load for the
duration of power interruption of
a reliable utility source.
Emergency Standby Power (ESP)
is in accordance with ISO 8528.
Fuel Stop power in accordance
with ISO 3046, AS 2789, DIN
6271 and BS 5514.
Applicable for supplying power to
a constant electrical load for
limited hours. Limited Time
Running Power (LTP) is in
accordance with ISO 8528.
Applicable for supplying power
to varying electrical load for
unlimited hours. Prime Power
(PRP) is in accordance with ISO
8528. Ten percent overload
capability is available in
accordance with ISO 3046,
AS 2789, DIN 6271 and BS
5514.
Applicable for supplying power
continuously to a constant
electrical load for unlimited
hours. Continuous Power (COP)
is in accordance with ISO 8528,
ISO 3046, AS 2789, DIN 6271
and BS 5514.
Our energy working for you.™
www.cumminspower.com
2011 Cummins Power Generation Inc. All rights reserved. Cummins Power Generation and Cummins are registered trademarks of Cummins Inc.
“Our energy working for you.” is a trademark of Cummins Power Generation. Specifications are subject to change without notice.
D-3336h (10/11)
Alternator data Voltage Connection1
temp rise
degrees C Duty2
Single
phase
factor3
Max
surge
kVA4
Winding
No.
Alternator
data sheet
Feature
Code
380 Wye, 3-phase 150/125/105 S/P/C 7327 13 ADS-515 B595
380 Wye, 3-phase 125/105/80 S/P/C 7327 13 ADS-515 B598
380 Wye, 3-phase 105/80 S/P 7327 13 ADS-515 B599
380 Wye, 3-phase 80 S 7963 13 ADS-516 B660
440 Wye, 3-phase 125/105/80 S/P/C 7361 312 ADS-334 B663
440 Wye, 3-phase 105 S 7284 12 ADS-515 B665
480 Wye, 3-phase 125/105/80 S/P/C 7361 312 ADS-334 B462
480 Wye, 3-phase 105/80 S/P 7695 312 ADS-335 B463
480 Wye, 3-phase 125/105 P/C 6716 312 ADS-332 B464
480 Wye, 3-phase 80 S 8412 12 ADS-516 B601
480 Wye, 3-phase 80 P 8412 12 ADS-516 B694
480 Wye, 3-phase 105 S 7695 12 ADS-517 B796
600 Wye, 3-phase 125/105/80 S/P/C 7361 07 ADS-334 B465
600 Wye, 3-phase 105/80 S/P 7695 07 ADS-335 B301
600 Wye, 3-phase 125/105 P/C 6716 07 ADS-333 B466
600 Wye, 3-phase 80 S 7265 07 ADS-516 B604
4160 Wye, 3-phase 125/105/80 S/P/C 6307 51 ADS-518 B467
4160 Wye, 3-phase 105/80 S/P 6307 51 ADS-518 B313
4160 Wye, 3-phase 80 S 6307 51 ADS-518 B605
4160 Wye, 3-phase 105 S 6307 51 ADS-520 B795
12470-13800 Wye, 3-phase 125/105/80 S/P/C 6062 91 ADS-521 B448
12470 Wye, 3-phase 105/80 S/P 6038 87 ADS-521 B567
13200-13800 Wye, 3-phase 105/80 S/P 6062 91 ADS-521 B612
12470 Wye, 3-phase 80 S 6685 87 ADS-522 B607
13200-13800 Wye, 3-phase 80 S 8012 91 ADS-523 B628
13800 Wye, 3-phase 80 S 6833 91 ADS-521 B610
13800 Wye, 3-phase 105 S 6062 91 ADS-523 B797
Notes:
1 Limited single phase capability is available from some three phase rated configurations. To obtain single phase rating, multipy the three phase
kW rating by the Single Phase Factor3. All single phase ratings are at unity power factor.
2 Standby (S), Prime (P) and Continuous ratings (C).
3 Factor for the Single Phase Output from Three Phase Alternator formula listed below.
4 Maximum rated starting kVA that results in a minimum of 90% of rated sustained voltage during starting.
Formulas for calculating full load currents:
Three phase output Single phase output