1 - 50 of 75 listings
3" x 3' Chemineer, Sieve Tray Column, (5) trays on 6" spacing, 1/2 HP, Stainless Steel plates
Machinery & Equipment Co | Brisbane, CA
Category: Columns
Seller: Machinery & Equipment Co
Location: Brisbane, CA
Mfr: Chemineer
Chemineer 3"x3' Stainless Steel Sieve Tray Column - Glass-lined column featuring 5 sieve trays on 6" spacing. Includes a 1/2 HP variable-speed agitator drive, stainless steel plates, and measures 3" in diameter x 3' height. (Serial #3-495)., Diameter: 3" X 3', Basis: FOB.
4" x 5' BE Peterson Distillation Column Reboiler Unit, 316 Stainless Steel, 200 psi, 270°F, 2024
Federal Equipment Company | Cleveland, OH
Category: Columns
Seller: Federal Equipment Company
Location: Cleveland, OH
Year: 2024
Used BE Peterson distillation column reboiler unit, 316 stainless steel construction with 4" diameter x 60" high column section rated 200 psi at 270 f, 15 gallon BE Peterson distillation pot, 316 stainless steel construction, approximately 12" diameter x 36" straight side, on legs, (1) 30 gallon BE Peterson knock out ...more
5" PFA lined column, jacketed, #3457-9
Federal Equipment Company | Cleveland, OH
Category: Columns
Seller: Federal Equipment Company
Location: Cleveland, OH
Mfr: Pfa
Used 6" PFA lined column, jacketed.
6" x 3' Edlon-PSI ION exchange column, carbon steel, PTFE lined, rated 150 psi at 200 f, 4 gallon capacity, 1998 (2 available)
Federal Equipment Company | Cleveland, OH
Category: Columns
Seller: Federal Equipment Company
Location: Cleveland, OH
Used 6" x 36" Edlon-PSI ION exchange column, carbon steel construction, PTFE lined, rated 150 psi and full vacuum at 200 f, 4 gallon capacity, serial# 5625, national board# 44, built 1998.
6" x 17' Cousins, Distillation Pot Still, 150 psi, 575 F, 12 sq.ft.. Condensor, 20 gallon Accumulator/Decentor, 1997
Aaron Equipment Co | Schaumburg, IL
Category: Columns
Seller: Aaron Equipment Co
Location: Schaumburg, IL
Mfr: Cousins
Year: 1997
used- cousins distillation pot still, 50 gallon, inconel 600 and 316 stainless steel construction, with 50 gallon horizontal still pot tank. rated 150 psi and full vacuum at 575 degrees f internal. jacket rated 150 psi at 575 degrees f. 6" diameter x 204" high distillation column, rated 100 psi and full vacuum at 575 ...more
Get email updates for newly added Columns
Columns (also known as distillation or separation columns) are tall, cylindrical vessels used in chemical processing, oil refining, and other industries to separate mixtures based on component volatility or density. Through processes like distillation, absorption, or stripping, columns facilitate the isolation of specific substances from a mixture, such as separating crude oil into various fuels.
6" PFA Lined Column, Jacketed
Aaron Equipment Co | Schaumburg, IL
Category: Columns
Seller: Aaron Equipment Co
Location: Schaumburg, IL
used- 6" pfa jacketed lined column.
6" PFA Lined Column, jacketed, #3457-10
Federal Equipment Company | Cleveland, OH
Category: Columns
Seller: Federal Equipment Company
Location: Cleveland, OH
Used 6" PFA lined column, jacketed.
8" x 5' Pfaudler, glass lined pipe, #23887
Federal Equipment Company | Cleveland, OH
Category: Columns
Seller: Federal Equipment Company
Location: Cleveland, OH
Mfr: Pfaudler
Unused 8" Pfaudler glass-lined pipe. 8" diameter x 5' long.
11" x 8' Tower Iron Works, full vacuum, 400°F, Stainless Steel
EcReCon Inc. | Pedericktown, NJ
Category: Columns
Seller: EcReCon Inc.
Location: Pedericktown, NJ
Year: 1966
, Stainless steel column rated Full Vacuum @ 400 degF. 11" diameter x 96" L. Built by Tower Iron Works Inc., 1966 TOWER IRON WORKS INC., Diameter in Inches. 11 in, Length in Ft. 8 ft, PSIG. Full Vacuum (FV), Temp (F). 400, Shell Mat. Stainless Steel, Stamped. U-Stamp.
12" x 15' Ardeth Engineering #D-321, column, Stainless Steel, 14.5 psi, dish top & bottom, 1992, #45912, 1992
Federal Equipment Company | Cleveland, OH
Category: Columns
Seller: Federal Equipment Company
Location: Cleveland, OH
Mfr: Ardeth
Year: 1992
Used 15' Ardeth Engineering column, model D-321, stainless steel construction, approximately 12" diameter x 15' straight side, dish top and bottom, rated 1 bar (14.5 psi) at 40°C internal, 2" top nozzle, 10" side access, (2) 2", (2) 1", 1" center bottom outlet, skirt mounted, approximately 235" overall ...more
12" x 17.6' Omnifab, 45 psi, Stainless Steel column, #31179
Federal Equipment Company | Cleveland, OH
Category: Columns
Seller: Federal Equipment Company
Location: Cleveland, OH
Mfr: Stainless
Used Omnifab column, stainless steel construction, 12" diameter x 17'6" straight side, dish top, cone bottom, 7' packed section, rated 45 psi and full vacuum at 600 F, 4", (2)2", (4)1" side nozzles, 2" bottom outlet, serial# B11335.91, national board# 268, 1991.
12" x 18' Industrial Process, 304 Stainless Steel, full vac.@ 300°F int, 3" packing sec.less packing, 26" L bonnet,NB #114,1992, #47818, 1992
Federal Equipment Company | Cleveland, OH
Category: Columns
Seller: Federal Equipment Company
Location: Cleveland, OH
Mfr: Industrial Process
Year: 1992
Used Industrial Process Equipment Column, 304 stainless steel construction, rated full vacuum at 300 f internal, approximately 12" diameter x 18'2" overall height, 12' 3" packing section less packing with 6" side nozzle, approximate 30" middle section with (2)1" nozzles, 2" top nozzle, approximately 26" long ...more
12" x 19' Owens Illinois Tool Works, glass lined packed column, 1976
Perry Videx LLC | Hainesport, NJ
Category: Columns
Seller: Perry Videx LLC
Location: Hainesport, NJ
Mfr: Illinois Tool Works
Year: 1976
Used 12" diameter X 19' Owens Illinois glass lined packed column. New 1976., OWENS ILLINOIS 12" X 19'.
12" x 23' Ceramic Coatings, 90 psi @ 500°F, high glass lined packed column
Perry Videx LLC | Hainesport, NJ
Category: Columns
Seller: Perry Videx LLC
Location: Hainesport, NJ
Mfr: Ceramic Coatings
Used Ceramic Coatings 12" diameter X 23' high glass lined packed column. Rated 90 psi @ 500F., CERAMIC COATINGS 12" X 23'.
14" x 16' Roark Enterprises, 175 psig @ -20°F/300°F, vertical Carbon Steel column, 1995
Perry Videx LLC | Hainesport, NJ
Category: Columns
Seller: Perry Videx LLC
Location: Hainesport, NJ
Year: 1995
Used Roark Enterprises Inc. vertical carbon steel column. 14" diameter X 16'8.75" high. 175 psig @ -20F/300F design pressure. Packing 10' of 1" stainless steel pall rings. Lug mounted. Built 1995., 1995 ROARK ENTERPRISES 14" X 16'.
16" x 6' 11" Five Star Industrial, 53 psi @ 150°F, 304 Stainless Steel column
Perry Videx LLC | Hainesport, NJ
Category: Columns
Seller: Perry Videx LLC
Location: Hainesport, NJ
Mfr: Star
Used 304 stainless steel column. 1st section - 16" diameter X 6'11" straight side; 2nd section - 30" diameter X 10'5" straight side; 20'11.5" overall. Rated 53 psi/full vacuum @ 150F. Stainless steel heads. (3) 8" and (2) 4" nozzles. Lug mounts. Manufactured by Five Star Industrial Services., FIVE STAR ...more
16" x 6' 11" Five Star Industrial, 53 psi @ 150°F, 304 Stainless Steel column
Perry Videx LLC | Hainesport, NJ
Category: Columns
Seller: Perry Videx LLC
Location: Hainesport, NJ
Mfr: Star
Used 304 stainless steel column. 1st section - 16" diameter X 6'11" straight side; 2nd section - 30" diameter X 10'5" straight side; 20'11.5" overall. Rated 53 psi/full vacuum @ 150F. Stainless steel heads. (3) 8" and (2) 4" nozzles. Lug mounts., Manufactured by Five Star Industrial Services., FIVE STAR ...more
16" x 25' PX Engineering Co., 90 psi @ 284°F, Stainless Steel packed column, horizontal U-tube condenser mounted on top, 1966
Perry Videx LLC | Hainesport, NJ
Category: Columns
Seller: Perry Videx LLC
Location: Hainesport, NJ
Year: 1966
Used approximately 16" diameter X 25' high stainless steel packed type column (requires packing). ASME constructed for 90 psi @ 284F. With a horizontal U-tube condenser mounted on top. 23" high conical bottom head. Manufactured by PX Engineering Co. in 1966. Serial #074, NB #4., 1966 PX ENGINEERING 16" X 25'.
18" x 2.6' Pfaudler, 150 psi, glass lined column, #23834
Federal Equipment Company | Cleveland, OH
Category: Columns
Seller: Federal Equipment Company
Location: Cleveland, OH
Mfr: Pfaudler
Used 18" Pfaudler Glass Lined Column Section, 18" diameter X 30" long section, rated 150 PSI and full vacuum @ 650 degrees F, 4", 3", 2" nozzles, 3315 glass steel, Serial NO. E177-0962, Manufacture No. E679-8188A, National Board No. 37988. Unit reglassed in 1979 and unused.
18" x 3' x 26' Entex, 166 psi, 304L Entex Steel column, #24810
Federal Equipment Company | Cleveland, OH
Category: Columns
Seller: Federal Equipment Company
Location: Cleveland, OH
Mfr: Entex
Used Entex Column, 304L stainless steel construction, 18" diameter first stage x 36" second stage x 26' overall straight side, elliptical top and bottom, rated 166 PSI and full vacuum @ 400 degrees F, sectional design with 18" diameter x 28" straight side top, 18" diameter x 11'9" middle section, 36" diameter ...more
18" x 14' Bay Tank & Fabricating, 55 psi @ 392°F, 304L Stainless Steel packed column
Perry Videx LLC | Hainesport, NJ
Category: Columns
Seller: Perry Videx LLC
Location: Hainesport, NJ
Used 18" X 14' packed column. Designed for 8' packed (1" polypropylene) bed. 304L stainless steel shell. +15" WC to -15" WC. Rated 55 psi @ 392F. Manufactured by Bay Tank and Fabricating Company., BAY TANK & FABRICATING 18" X 14'.
18" x 14' Bay Tank & Fabricating, 55 psi @ 392°F, 304L Stainless Steel packed column
Perry Videx LLC | Hainesport, NJ
Category: Columns
Seller: Perry Videx LLC
Location: Hainesport, NJ
Used 18" X 14' packed column. Designed for 8' packed (1" polypropylene) bed. 304L stainless steel shell. +15" WC to -15" WC. Rated 55 psi @ 392F. Manufactured by Bay Tank and Fabricating Company., BAY TANK & FABRICATING 18" X 14'.
18" x 16' Pfaudler, 10 psi @ 300°F, Titanium Grade 2 Column
Perry Videx LLC | Hainesport, NJ
Category: Columns
Seller: Perry Videx LLC
Location: Hainesport, NJ
Mfr: Pfaudler
Used Pfaudler 18" diameter X 194" high titanium grade 2 column. (3) sections. TI-SB265-GR2. Rated 10 psi @ 300F. Pall rings internal. Has (3) 36" long legs., 1985 PFAUDLER 18" X 194".
18" x 16' Pfaudler, 10 psi @ 300°F, Titanium Grade 2 Column, 1985
Perry Videx LLC | Hainesport, NJ
Category: Columns
Seller: Perry Videx LLC
Location: Hainesport, NJ
Mfr: Pfaudler
Year: 1985
Used Pfaudler titanium grade 2 column. 18" diameter X 194" high. (3) sections. TI-SB265-GR2. Rated 10 psi @ 300F. Pall rings internal. S/N R385-1700. 1985. Has (3) 36" long legs., PFAUDLER 18" X 194".
18" x 18' 8" Robert Mitchell Co., 304L Stainless Steel column
Perry Videx LLC | Hainesport, NJ
Category: Columns
Seller: Perry Videx LLC
Location: Hainesport, NJ
Mfr: Mitchell
Used 18" diameter X 18'8" vertical type 304L stainless steel Robert Mitchell Co. packed column. (1) flat flanged carbon steel head, opposite end is stainless steel. Openings: 1- 8", 1- 2", side 1- 4", 2- 1-1/2", 1- 8", 2- 1". (4) lugs., ROBERT MITCHELL 18" X 18'8".
18" x 20' 6" Roark Enterprises, vertical 304 Stainless Steel column, 75 psig @ 175°F
Perry Videx LLC | Hainesport, NJ
Category: Columns
Seller: Perry Videx LLC
Location: Hainesport, NJ
Used Roark Enterprises vertical 304 stainless steel column. 18" diameter X 20'6" high. With 1" stainless steel pall rings. Rated 75 psig @ 175F design pressure. Lug mounted., ROARK ENTERPRISES 18" X 20'6".
20" x 22' Pfaudler, Glass Lined Column, 45 gallon, 100 psi, 500 F, 2017
Federal Equipment Company | Cleveland, OH
Category: Columns
Seller: Federal Equipment Company
Location: Cleveland, OH
Mfr: Pfaudler
Year: 2017
Used 267" Pfaudler glass lined column, model CL20-100, approximately 20" diameter x 267" straight side, 295" overall height, with 115" top section, 98" bottom section, rated 100 psi and full vacuum at 500 f, 45 gallon, 9119 glass, serial# 3141783A national board# 52851, built 2016, reglassed by Pfaudler, serial# ...more
20" x 22' Pfaudler, Glass Lined Column, 45 gallon, 100 psi, 500 F, 2016
Federal Equipment Company | Cleveland, OH
Category: Columns
Seller: Federal Equipment Company
Location: Cleveland, OH
Mfr: Pfaudler
Year: 2016
Used 267" Pfaudler glass lined column, model CL20-100, approximately 20" diameter x 267" straight side, 295" overall height, with 115" top section, 98" bottom section, rated 100 psi and full vacuum at 500 f, 45 gallon, 9119 glass, serial# 4196060A, national board# 52895, built 2016.
20" x 34' Koch, 50 psi, 304L Stainless Steel extraction column, #24800
Federal Equipment Company | Cleveland, OH
Category: Columns
Seller: Federal Equipment Company
Location: Cleveland, OH
Mfr: Koch
Unused Koch Extraction Column, 304L stainless steel construction, 40" diameter upper section x 20" diameter middle section x 40" diameter lower section x 53'1" overall straight side, dished bottom, rated 50 PSI and full vacuum @ 400 degrees F internal, sectional design with 40" diameter x 10' long upper and ...more
22" x 29' 3.5" Northland Stainless, Column, 904L Stainless Steel, 90 psi @400°F, 2010
Federal Equipment Company | Cleveland, OH
Category: Columns
Seller: Federal Equipment Company
Location: Cleveland, OH
Mfr: Northland
Year: 2010
Used 29' 3.5" Northland Stainless column, 904L stainless steel construction, approximately 22' diameter x 29' 3.5" straight side, rated 90 psi and full vacuum at 400 f internal, with 49.1875" top section, 96" long, 36" long, 96" long intermediate middle sections, 83.3125" bottom section, bolt on dish top ...more
22" x 40' McAbee, 200/FV PSIG, 325° /-49°F, 304L Stainless Steel
EcReCon Inc. | Pedericktown, NJ
Category: Columns
Seller: EcReCon Inc.
Location: Pedericktown, NJ
Year: 2012
, Unused Stainless Steel Distillation Column with Condenser. 22"/42" dia. X 40'5" T/T. Rated 200/FV PSI@ 325/-49 Deg.F. Bottom 5'11" is 42" dia. and the remainder of column is 22" dia. NB # 2395. Has Support trays, No packing available. Condenser is 72 Sq.FT. 304L SS Shell rated 170/vacuum @ 325 Deg.F. 304L SS ...more
23" x 10' DE Dietrich, glass lined column, 75 psi/full vacuum @ 300°F, 2005
Perry Videx LLC | Hainesport, NJ
Category: Columns
Seller: Perry Videx LLC
Location: Hainesport, NJ
Mfr: De Dietrich
Year: 2005
Reglassed and unused De Dietrich 23" diameter X 10' long glass lined column (4340001827). Type 3008 glass. Rated 75 psi/full vacuum @ 300F. With 18" head new in 2005 (4340001823) and 4' head. New in 2005 (4340001801)., DE DIETRICH 23" X 10'.
Baeurle & Morris 24" x 3.4' Baeuerle & Morris, 50 psi, 304L Stainless Steel, 400 deg.,vacuum, 35 donut trays, 1983
Midwest Steel Co | Houston, TX
Category: Columns
Seller: Midwest Steel Co
Location: Houston, TX
Mfr: Baeurle & Morris
Year: 1983
24" x 4' Tycon, 30 psi, glass lined column, #29747
Federal Equipment Company | Cleveland, OH
Category: Columns
Seller: Federal Equipment Company
Location: Cleveland, OH
Mfr: Tycon
Unused 24" x 48" Tycon Glass Lined Column, approximately 24" x 48" high, rated 30 psi and full vacuum at 280 f, 12" side manway, 8" to nozzle, 8'4" side nozzles, serial # 8901.1, national board # 536, built 2000.
24" x 7.3' Column, reflux chamber, glass lined, Ceramic Coatings (3 available)
Machinery & Equipment Co | Brisbane, CA
Category: Columns
Seller: Machinery & Equipment Co
Location: Brisbane, CA
Mfr: Ceramic Coatings
Year: 1996
(3) Column, reflux chamber/mist eliminator, 24" diameter x approximately 87" overall height (nozzle to nozzle), manufactured by Ceramic Coating, glass-lined, rated for 125 PSI/FV @ 450 degrees Fahrenheit, ASME, 6" center top opening, 12" center bottom opening, J-clamped 10" from bottom head & 24" from top head ...more
24" x 9' Tactical Fabrication, Ion Exchange Columns, (3) 24" diameter x 9' H columns w/ (1) 2.5"dia. & 1.5"dia. Inlets, 3" bottom discharge, 14" dia. Manway
Machinery & Equipment Co | Brisbane, CA
Category: Columns
Seller: Machinery & Equipment Co
Location: Brisbane, CA
Mfr: Tactical Fabrication
Ion exchange columns, including (3) 24" diameter X 9' high columns with each column having (3) top inlets; (1) 2-1/2" diameter center top & (2) 1-1/2" diameter. Bottom includes 3" center bottom discharge and 14" diameter bolted side bottom manway. Unitized on skid. Previously used for resin filtration at ...more
24" x 24' Pfaudler, 150 psi or F/V, glass lined column
Machinery & Equipment Co | Brisbane, CA
Category: Columns
Seller: Machinery & Equipment Co
Location: Brisbane, CA
Mfr: Pfaudler
Column, 24" diameter x 24' high, plus dished ends, glass-lined. Last used in chemical distillation process. Includes (2) main body sections manufactured by Pfaudler & DeDietrich with ceramic packing, Pfaudler section measures 24" x 14', rated for 150 PSI/FV @ 450 degrees Fahrenheit. (Pfaudler serial number ...more
24" x 28' APV, Stainless Steel Desulphurizing Column, Grape Juice SO2 Removal System, 15-Tray, 1000 IGPH, 1550 ppm to 100 ppm SO2
Aaron Equipment Co | Schaumburg, IL
Category: Columns
Seller: Aaron Equipment Co
Location: Schaumburg, IL
Mfr: Apv
used apv 24" x 28' stainless steel desulphurizing column | 15-tray | grape juice so2 removal system. the 1000 igph grape juice desulphuring system was for removing sulphur dioxide from 1550 to 100 ppm. unit includes preheater shell, tube heat exchanger, and sihi pump.
24" x 29' Gortech, 5 PSIG, 200° /-25°F, Stainless Steel
EcReCon Inc. | Pedericktown, NJ
Category: Columns
Seller: EcReCon Inc.
Location: Pedericktown, NJ
Year: 2007
, used Stainless Steel distillation column 24" diameter x 29'6". Built by GORTECH. Rated 5 PSI @ 200/-25 degF. 29'6" Overall length. Mounted on steel skirt., 2007 GORTECH., Diameter in Inches. 24 in, Length in Ft. 29 ft, PSIG. 5, Temp (F). 200/-25, Shell Mat. STAINLESS STEEL, Stamped. NB 3-2, Weight. ~5,000 ...more
24" x 61' Column, alcohol distilliation, 304L Stainless Steel
EcReCon Inc. | Pedericktown, NJ
Category: Columns
Seller: EcReCon Inc.
Location: Pedericktown, NJ
, 24" x 61' Stainless Steel Alcohol Distillation Column. Has Stainless Packing Rings. 71' Overall Height. (2) Sections: Top Section is 24" dia x 30' T/T (plus 12" for top head). Bottom Section is 24" dia x 31' T/T (btm skirt add 9'). Rectifier column/Rectification column. Previously used in system ...more
28" x 11' Pfaudler, 30 psi, glass lined column, #23868
Federal Equipment Company | Cleveland, OH
Category: Columns
Seller: Federal Equipment Company
Location: Cleveland, OH
Mfr: Pfaudler
Used 28" diameter X 11' high Pfaudler Glass Lined Column, Section 9115 glass, rated 30 psi and full vacuum at 280 f, (2) 3" inlet/outlets, (1) 12" X 16" side manway, serial# J016695, national board# 49028, built 1997.
30" x 10' DE Dietrich, glass lined column, 105 psi @ 500°F/-20°F, 2003
Perry Videx LLC | Hainesport, NJ
Category: Columns
Seller: Perry Videx LLC
Location: Hainesport, NJ
Mfr: De Dietrich
Year: 2003
Reglassed and unused De Dietrich 30" diameter X 10' long glass lined column (4340001811). Type 3009 glass. Rated 105 psi/full vacuum @ 500F/-20F. With (2) heads (4340001822). Built 2003., DE DIETRICH 30" X 10'.
30" x 54' -1/2" Ceramic Coatings, Column, reflux chamner/mist elliminator, 100 psi/FV @ 500°F, 6"/12" openings, 1993
Machinery & Equipment Co | Brisbane, CA
Category: Columns
Seller: Machinery & Equipment Co
Location: Brisbane, CA
Mfr: Ceramic Coatings
Year: 1993
Column, reflux chamber/mist eliminator, 30" diameter x 54-1/2" overall height (nozzle to nozzle), manufactured by Ceramic Coating, glass-lined, glass-type HT2000, rated for 100 PSI/FV @ 500 degrees Fahrenheit to -20 degrees Fahrenheit, ASME, 6" center top opening, 12" center bottom opening, J-clamped in middle of ...more
30" x 54' -1/2" Column, reflux chamber, Ceramic Coatings
Machinery & Equipment Co | Brisbane, CA
Category: Columns
Seller: Machinery & Equipment Co
Location: Brisbane, CA
Mfr: Ceramic Coatings
Year: 1994
Unused column, reflux chamber/mist eliminator, 30" diameter x 54-1/2" overall height (nozzle to nozzle), manufactured by Ceramic Coating, glass-lined, glass-type HT2000, rated for 100 PSI/FV at 500 degrees Fahrenheit to negative 20 degrees Fahrenheit, ASME, 6" center top opening, 12" center bottom opening, J-clamped ...more
30" x 60' A & B Process Systems #SRXC, Stainless Steel Column, 50 PSI, 350°F, 2011
Machinery & Equipment Co | Brisbane, CA
Category: Columns
Seller: Machinery & Equipment Co
Location: Brisbane, CA
Mfr: A & B Process Systems
Year: 2011
A&B Processing Rectifier/Stripper Column - Massive 30" diameter x 60' height column with 316 stainless steel construction. Rated for 50 PSI and a temperature range between -30F and 350F. Includes 30 trays. Manufactured in 2011., Diameter: 30", Type: Rectifier/Stripper Column, Materials of Construction: 316 ...more
30" x 72' Column, alcohol distillation, 304L Stainless Steel
EcReCon Inc. | Pedericktown, NJ
Category: Columns
Seller: EcReCon Inc.
Location: Pedericktown, NJ
, 30" x 72'6" Stainless Steel Alcohol Distillation Column. Approx. (40) Sieve Trays on 18" spacing. 81' Overall Height. (2) Sections: Top Section is 30" dia x 40' T/T (plus 14" for top head). Bottom Section is 30" dia x 32'6" T/T (btm skirt add 7'6"). Stripper column. Previously used in a System ...more
36" x 23' Trinity Steel, 15 PSIG, 300°F, 304 Stainless Steel
EcReCon Inc. | Pedericktown, NJ
Category: Columns
Seller: EcReCon Inc.
Location: Pedericktown, NJ
Mfr: Trinity
Year: 1964
, Stainless Steel Coulmn. 36" diameter x 23' Height, with Packing., 1964 TRINITY STEEL., Diameter in Inches. 36 in, Length in Ft. 23 ft, PSIG. 15, Temp (F). 300, Shell Mat. 304 Stainless Steel, Weight. 4000.
36" x 24.7' CR Construction Inc., Acid Reduction Column, Stainless Steel, 50 psi @ -20 to 250 F, 24" Man Way, 2007
Aaron Equipment Co | Schaumburg, IL
Category: Columns
Seller: Aaron Equipment Co
Location: Schaumburg, IL
Mfr: Cr Construction Inc.
Year: 2007
used- dcr construction acid reduction column, 304 stainless steel, vertical. 36" diameter x 297" straight side, 2:1 elliptical top and bottom. approximate 49' overall height. internal rated 50 psi at -20 to 250 degrees f. openings top 18" vapor outlet, side 6" liquid inlet, side top 24" man way with cover & ...more
36" x 37' Ricsa, Demethanizer Column, in Ricsa Steel, Maximum Pressure 752.3 to 150°F, new
Myron Bowling Auctioneers Mexico | Metepec, MX
Category: Columns
Seller: Myron Bowling Auctioneers Mexico
Location: Torreón, Coahuila, Mexico
Mfr: Ricsa
(NEW) RICSA Brand Demethanizer Column, in Stainless Steel, Maximum Pressure 752.3 to 150 °F, Minimum Temperature -205 °F with PSI 752.3, Nomil Capacity 2069 gallons. Inner Diameter 36", Height 450", Weight 27,677 Lbs. NB 1167. YEAR 2018., (NUEVO) Columna Demetanizadora Marca RICSA, enn Acero Inoxidable ...more
36" x 40' Solzer, Sulzer Steel Column, 100 PSI @ 600°F, (22 available) Trays
Machinery & Equipment Co | Brisbane, CA
Category: Columns
Seller: Machinery & Equipment Co
Location: Brisbane, CA
Mfr: Sulzer
36-Inch Diameter Distillation Column - Fabricated from 316 stainless steel, rated for 100 PSI @ 600F. Measures 40' high and includes (22) trays. Remanufactured by Sulzer., Diameter: 36", Type: Distillation Column, Materials of Construction: 316 Stainless Steel, Basis: As Is, Where Is.














































