For Sale by Midwest Steel Co
Surplus Record Dealer Since 1991
Location: Houston, TX
Contact Sales Dept.
Phone Number: 713...> Show Phone Number 713-991-7843
Let the seller know you found their listing on Surplus Record!
Description
ONE (1) USED; TITAN METAL FABRICATORS; YR. 2015; SHELL: 150/FV @ 100 F; TUBES: 150/FV @ 150 F; 97Ta 3W/TUBES WITH TURBULATOR INSERTS; CS SHELL; NB 1533; SN 22032-1-1; 40 SQ.FT
Get Your Price from Midwest Steel Co!
Buyers Who Viewed This Listing Also Viewed:
7 Sq.ft., 150 psi shell, 150 psi tube, Pfaudler, Heat Exchanger, Carbon Steel, U-tube, 1991
Seller: Federal Equipment Company
Location: Cleveland, OH
Mfr: Pfaudler
Year: 1991
Used approximately 7 sq ft Pfaudler shell and tube heat exchanger, carbon steel tubes, shell and bonnet, U-tube design, with (16).75" diameter U-tubes, rated 150 psi at 400 f, shell rated 150 psi at 400 f, serial# R391-1969, national board# 46635, built 1991.
39 sq.ft., 150 psi shell, 150 psi tube, Doyle & Roth, heat exchanger, 500°F shell, 400°F tube, 2015
Seller: Louisiana Chemical Equip Co
Location: Baton Rouge, LA
Year: 2015
ITEM NO : 110472 QTY : 1 ALLOY : C SQ.FT. : 39 MATERIAL (S) : CS MATERIAL (T) : CS MATERIAL (H) : CS PSI (S) : 150FV PSI (T) : 150FV TEMP. DEG. F (S) : 500 TEMP. DEG. F (T) : 400 TUBE DIAMETER IN" :.75 TUBE LENGTH FT'IN" : 10'0" TUBE HOLES : 20 TUBE PITCH : 15/16" SQ. TUBE WALL :.083" ...more
185 sq.ft., 150 psi shell, 150 psi tube, Bell & Gossett, Shell & Tube Heat Exchanger, (330) 5/8" diameter x 3' 6" L multi-tubes, 18 gallon coil, 2001
Seller: Genemco
Location: Hearne, TX
Mfr: Bell & Gossett
Year: 2001
2001 Bell & Gossett Shell & Tube Heat Exchanger. S/N: 782912-01. Part No: BY526200080600. Carbon steel construction. (330) 5/8 in. dia. x 3 ft. 6 in. L multi-tubes. Heat transfer surface area: approx. 185 sq. ft. Coil volume: 18 gal. Shell side MAWP: 150 psi @ 375F, MDMT: -20F @ 150 psi. Tube side MAWP: 150 ...more
3 sq.ft., 150 psi shell, 150 psi tube, Pfaudler, Shell & Tube Heat Exchanger, carbon steel, (7) 0.75" diameter U-Tubes, 400°F, 1991 (4 available)
Seller: Federal Equipment Company
Location: Cleveland, OH
Mfr: Pfaudler
Used approximately 3 sq ft Pfaudler shell and tube heat exchanger, carbon steel tubes, shell and bonnet, U-tube design, with (7).75" diameter U-tubes, rated 150 psi at 400 f, shell rated 150 psi at 400 f, serial# R391-1962, national board# 46596, built 1991.
2075 sq.ft., 150 psi shell, 150 psi tube, Energy Exchanger, horizontal heat exchanger, 145°F, 2011
Seller: Louisiana Chemical Equip Co
Location: Baton Rouge, LA
Mfr: Energy Exchanger
Year: 2011
ITEM NO : 112951 QTY : 1 ALLOY : C SQ.FT. : 2075 MATERIAL (S) : CS MATERIAL (T) : CS MATERIAL (H) : CS PSI (S) : 150FV PSI (T) : 150FV TEMP. DEG. F (S) : 275 TEMP. DEG. F (T) : 145 TUBE DIAMETER IN" :.75 TUBE LENGTH FT'IN" : 24'0" TUBE HOLES : 444 TUBE WALL :.083" V/H : H CODE : NB TEMA ...more