Manufacturer: Superior
Model: 4-X-1506
Year: 1997
HP: 350.00
Pounds per Square Inch: 150
Stock # BSSB350HP301
For Sale by C3 Surplus LLC
Surplus Record Dealer Since 2020
Location: Miami, FL
Contact Vernon Mccoy
Phone Number: 305...> Show Phone Number 305-428-2777
Let the seller know you found their listing on Surplus Record!
Description
OVERVIEW
This is a Superior Boiler Works (Mohawk Boiler-Burner Unit) packaged firetube steam boiler, Model 4-X-1506, rated 350 boiler horsepower. Factory-built by Superior Boiler Works Inc. of Hutchinson, Kansas, with an Industrial Combustion (Division of Aqua-Chem Inc.) burner control system, water column and gauge glass, and complete trim. Low-pressure design, 150 PSI steam maximum allowable working pressure. Year built 1997.
The unit carries a documented, active inspection history, most recently inspected internally on 9-29-25, with next inspection due 9-29-26. It is registered under National Board No. 13357 and holds current Liberty Mutual and HSB (Hartford Steam Boiler) inspection tags. Ready for inspection, contact us to schedule.
EQUIPMENT SPECIFICATIONS
Boiler:
- Manufacturer: Superior Boiler Works, Inc., Hutchinson, KS, USA (Mohawk Boiler-Burner Unit)
- Equipment Type: Packaged Firetube Steam Boiler
- Model: 4-X-1506
- Boiler Horsepower: 350 HP
- Maximum Allowable Working Pressure (MAWP): 150 PSI Steam
- Heating Surface: 1,506 sq ft
- Minimum Valve Capacity: 12,048 lbs/hr (BTU/hr)
- Serial No. / National Board No.: 13357
- Year Built: 1997
Burner and Combustion:
- Industrial Combustion (Division of Aqua-Chem, Inc.) burner control system
- Digital display control panel with manual switches
Trim and Controls:
- Water column with gauge glass and low-water cutoff (LWCO)
- Steam pressure gauge
- Factory control panel and disconnect
Ancillary Equipment:
- Vertical multistage feed pump
- Horizontal feedwater/storage tank on stand
- Associated piping, valves, and feed system components
Inspection and Compliance:
- Liberty Mutual Boiler and Pressure Vessel Inspection tag on file
- HSB (Hartford Steam Boiler) tag, last inspected 9-29-25, next required 9-29-26
- NFPA installation clearances: 18 in. top / 48 in. front / 18 in. sides-rear-flue at 50 PSI; 48 in. top / 96 in. front / 36 in. sides-rear-flue at >50 PSI
- Must be installed on noncombustible flooring
KEY FEATURES AND BENEFITS
- Proven Superior Boiler Works (Mohawk) firetube design
- 350 HP, 1,506 sq ft heating surface
- 150 PSI steam rating
- Documented, current inspection history (HSB, Liberty Mutual)
- Feedwater pump and storage tank included
- National Board registered (No. 13357)
SYSTEM COMPONENTS
- Boiler: 4-X-1506, 350 HP, built 1997, 150 PSI MAWP, gauge glass, water column, steam pressure gauge
- Burner and Controls: Industrial Combustion forced-draft burner control system, factory panel
- Feedwater System: vertical multistage feed pump, horizontal feedwater/storage tank, piping and valves
- Documentation: National Board No. 13357, HSB and Liberty Mutual inspection tags
SPECIFICATIONS SUMMARY
- Manufacturer: Superior Boiler Works, Inc.
- Model: 4-X-1506
- Boiler Horsepower: 350 HP
- MAWP: 150 PSI Steam
- Heating Surface: 1,506 sq ft
- Minimum Valve Capacity: 12,048 lbs/hr (BTU/hr)
- Year Built: 1997
- Serial No. / National Board No.: 13357
- Includes: Feedwater pump, feedwater/storage tank, burner control system
- Condition: Used, inspected, in service prior to removal
- Last Inspection: 9-29-25 (internal), next required 9-29-26
ADDITIONAL INFORMATION
- Condition: Used, documented inspection history, reported in working condition prior to removal
- Manufacturer: Superior Boiler Works, Inc., Hutchinson, KS
- Model: 4-X-1506, 350 HP
- Year Built: 1997
- Rated: 150 PSI MAWP, 1,506 sq ft heating surface
- National Board No.: 13357
- Inspection: Welcome, contact us to schedule
Location: Ohio
This is a Superior Boiler Works (Mohawk Boiler-Burner Unit) packaged firetube steam boiler, Model 4-X-1506, rated 350 boiler horsepower. Factory-built by Superior Boiler Works Inc. of Hutchinson, Kansas, with an Industrial Combustion (Division of Aqua-Chem Inc.) burner control system, water column and gauge glass, and complete trim. Low-pressure design, 150 PSI steam maximum allowable working pressure. Year built 1997.
The unit carries a documented, active inspection history, most recently inspected internally on 9-29-25, with next inspection due 9-29-26. It is registered under National Board No. 13357 and holds current Liberty Mutual and HSB (Hartford Steam Boiler) inspection tags. Ready for inspection, contact us to schedule.
EQUIPMENT SPECIFICATIONS
Boiler:
- Manufacturer: Superior Boiler Works, Inc., Hutchinson, KS, USA (Mohawk Boiler-Burner Unit)
- Equipment Type: Packaged Firetube Steam Boiler
- Model: 4-X-1506
- Boiler Horsepower: 350 HP
- Maximum Allowable Working Pressure (MAWP): 150 PSI Steam
- Heating Surface: 1,506 sq ft
- Minimum Valve Capacity: 12,048 lbs/hr (BTU/hr)
- Serial No. / National Board No.: 13357
- Year Built: 1997
Burner and Combustion:
- Industrial Combustion (Division of Aqua-Chem, Inc.) burner control system
- Digital display control panel with manual switches
Trim and Controls:
- Water column with gauge glass and low-water cutoff (LWCO)
- Steam pressure gauge
- Factory control panel and disconnect
Ancillary Equipment:
- Vertical multistage feed pump
- Horizontal feedwater/storage tank on stand
- Associated piping, valves, and feed system components
Inspection and Compliance:
- Liberty Mutual Boiler and Pressure Vessel Inspection tag on file
- HSB (Hartford Steam Boiler) tag, last inspected 9-29-25, next required 9-29-26
- NFPA installation clearances: 18 in. top / 48 in. front / 18 in. sides-rear-flue at 50 PSI; 48 in. top / 96 in. front / 36 in. sides-rear-flue at >50 PSI
- Must be installed on noncombustible flooring
KEY FEATURES AND BENEFITS
- Proven Superior Boiler Works (Mohawk) firetube design
- 350 HP, 1,506 sq ft heating surface
- 150 PSI steam rating
- Documented, current inspection history (HSB, Liberty Mutual)
- Feedwater pump and storage tank included
- National Board registered (No. 13357)
SYSTEM COMPONENTS
- Boiler: 4-X-1506, 350 HP, built 1997, 150 PSI MAWP, gauge glass, water column, steam pressure gauge
- Burner and Controls: Industrial Combustion forced-draft burner control system, factory panel
- Feedwater System: vertical multistage feed pump, horizontal feedwater/storage tank, piping and valves
- Documentation: National Board No. 13357, HSB and Liberty Mutual inspection tags
SPECIFICATIONS SUMMARY
- Manufacturer: Superior Boiler Works, Inc.
- Model: 4-X-1506
- Boiler Horsepower: 350 HP
- MAWP: 150 PSI Steam
- Heating Surface: 1,506 sq ft
- Minimum Valve Capacity: 12,048 lbs/hr (BTU/hr)
- Year Built: 1997
- Serial No. / National Board No.: 13357
- Includes: Feedwater pump, feedwater/storage tank, burner control system
- Condition: Used, inspected, in service prior to removal
- Last Inspection: 9-29-25 (internal), next required 9-29-26
ADDITIONAL INFORMATION
- Condition: Used, documented inspection history, reported in working condition prior to removal
- Manufacturer: Superior Boiler Works, Inc., Hutchinson, KS
- Model: 4-X-1506, 350 HP
- Year Built: 1997
- Rated: 150 PSI MAWP, 1,506 sq ft heating surface
- National Board No.: 13357
- Inspection: Welcome, contact us to schedule
Location: Ohio
Get Your Price from C3 Surplus LLC!
Buyers Who Viewed This Listing Also Viewed:
JUST ADDED!
350 HP Cleaver-Brooks #CBEX-700-350-150ST, firetube, 9ppm NOx, 11.716M BTUH, 150 PSI, 2017
Category: Firetube Boilers
Seller: C3 Surplus LLC
Location: Miami, FL
Mfr: Cleaver-Brooks
Model: CBEX-700-350-150ST
Year: 2017
Cleaver-Brooks —, - Model: CBEX-F 700-350-150ST, - Serial: T6136-1-1, - National Board #20259, - Year: 2017, - 350 HP (gross output 11,716,000 BTU/hr — the math confirms 350 HP exactly), - Max working pressure: 150 PSI steam, - Fuel: natural gas only (all oil fields marked NA), - Max input 14,288,000 ...more
350 HP Kewanee #H3S-350G, Nat gas, 150 psi steam, refurbished w/warranty
Category: Firetube Boilers
Seller: Power Mechanical Inc
Location: Newport News, VA
Mfr: Kewanee
Model: H3S-350G
350 HP Cleaver-Brooks #CEW200-350-150, 150 psi, firetube boiler, 250 HP, CB 3-pass, 1994, Boiler can be fully reconditioned, with new burner,
Category: Firetube Boilers
Seller: Ware Inc
Location: Louisville, KY
Mfr: Cleaver-Brooks
Model: CEW200-350-150
Year: 1994
350 HP Cleaver-Brooks #CBLE-200-350-150ST, Packaged Steam Boiler, 150 PSI, AB PowerFlex 400 VFD, 2015
Category: Firetube Boilers
Seller: C3 Surplus LLC
Location: Miami, FL
Mfr: Cleaver-Brooks
Model: CBLE-200-350-150ST
Year: 2015
OVERVIEW, This is a Cleaver Brooks Model CBLE 200-350-150ST packaged firetube steam boiler, rated 350 boiler horsepower. Factory-built by Cleaver Brooks, Thomasville, Georgia, USA, in 2015. Dual-fuel design, fired on natural gas or No. 2 oil, with a low NOx emission rating of 30 PPM. Maximum working pressure 150 PSI ...more
350 HP Smith Hughes #RT-350A, RENTAL, 250 psig, 12075 pph, Natural Gas, #2 Fuel oil fired, low NOx, firetube steam boiler, trailer enclosed
Category: Firetube Boilers
Seller: Smith Hughes Co
Location: Cincinnati, OH
Mfr: Smith Hughes
Model: RT-350A
Year: 2023
RT-350A Mobile Boiler Room, 350 HP, 250 PSIG, Natural Gas, No. 2 Fuel Oil Fired, Complete boiler room package is designed to be placed in service at customer specified location with minimal, on-site work., INCLUDES:, • 40' Enclosed Container and Chassis, • (1) 350 HP Superior firetube steam boiler ...more