For Sale by Buckeye Power Systems

Surplus Record Dealer Since 2025
David Richey
901-37...> Show Seller's Phone Number 901-379-8097 Let the seller know you found their listing on Surplus Record!
Description
Model C200D6D | 120/208V 3-Phase | Level 1 Sound Enclosure | 24-Hour Subbase Fuel Tank
IN STOCK - Ready to Ship
The Cummins C200D6D Protects What Matters Most
Keep your business running when the power goes out. The Cummins C200D6D diesel generator safeguards your operations, inventory, productivity, and profitability with reliable backup power you can count on.
Complete Power Solution
This 200kW diesel generator is a fully integrated standby power system designed for commercial applications. It arrives ready to install with a weather-resistant Level 1 aluminum sound enclosure and integrated 24-hour fuel tank. Certified to meet U.S. EPA Tier 3, UL 2200, and NFPA 110 Type 10 standards, this generator delivers proven performance when your business needs it most.
Built for Reliability
Heavy-Duty Cummins EngineAt the heart of this generator is a rugged 6.7-liter inline 6-cylinder diesel engine with a cast iron block. This liquid-cooled, 4-cycle industrial engine runs at 1800 RPM for exceptionally quiet operation and long-lasting durability. It responds quickly to load changes while maintaining low emissions, providing dependable power year after year.
High-Performance AlternatorThe brushless alternator features low reactance 2/3 pitch windings that excel at starting motors and handling demanding electrical loads. It produces clean power with minimal waveform distortion, even with sensitive electronics and nonlinear loads, and offers robust fault-clearing capability during short-circuit conditions.
Intelligent Control SystemThe PowerCommand 1.1 electronic control system manages every aspect of generator operation. It automatically starts and stops the unit, precisely regulates frequency and voltage, displays system status and alarms, provides output metering, and shuts down safely if faults are detected. The system meets NFPA 110 Level 1 compliance requirements for critical applications.
Weather-Resistant EnclosureThe green aluminum sound-attenuated enclosure is engineered to withstand 180 mph wind loads per ASCE 7-10 standards while reducing operational noise. It protects internal components from the elements while maintaining accessibility for routine maintenance.
Integrated Fuel SystemThe 351 gallon dual-wall subbase fuel tank provides 24 hours of runtime at full load and is UL 142 and ULC-S601 listed for safety and compliance.
Regional Fuel Tank Standard Features:
UL 142 and ULC-S601 listed - Minimum 110% secondary IBC 2012 and 2015 certified - All optional features are seismically certified with this range of tanks and generator sets. Requires factory-installed 2 ft vent extensions or higher.
UL 142 & ULC-S601 listed - Minimum 125% secondary containment capacity. NFPA & IFC - Capable of meeting NFPA 30, NFPA 110, and IFC codes with available factory-installed optional features.
Emergency pressure relief vents - Ensure adequate ventilation of the primary and secondary tank compartments under extreme temperature and emergency conditions.
Normal atmospheric vent - Mushroom style vent ensures adequate venting of the primary tank during fill, generator set running, and temperature variations. Raised above fuel fill.
Raised fuel fill - Includes lockable sealed fuel cap. Lifting eyes - Allow lifting of fuel tank with generator set installed.
Certifications & Standards
This generator meets rigorous industry standards including U.S. EPA Tier 3 emissions, UL 2200 safety, NFPA 110 Type 10, ISO 1001, and International Building Code (IBC) Seismic 2012. It is NFPA Type 1 capable for critical backup power applications.
Warranty & Support
Includes a comprehensive 2-year or 1,000-hour standby warranty. Extended warranty options are available upon request.
Specifications
Power Output: 200kW at 120/208V 3-Phase
Model: C200D6D
Fuel: Diesel
Fuel Tank Capacity: 351 gallons
Enclosure: Level 1 Sound Attenuated
Control System: PowerCommand 1.1
Remote Monitoring: Available with optional accessory equipment
Automatic Transfer Switch: Not included. See Cummins OTEC Series Switches
Weight (with fuel tank): 5,112 lbs
Dimensions (with fuel tank): 180"L x 40"W x 93"H
Certifications: EPA Tier 3, UL 2200, NFPA 110 Type 10, ISO 1001, IBC Seismic 2012
DOWNLOADS:
Spec Sheet - C200D6D
Ready to Secure Your Power?
Contact Buckeye Power Systems today to discuss transfer switch options, shipping, and how this generator can protect your business operations.
RELATED C200D6D Generator:
Cummins C200D6D - 200kW @ 277/480V 3-Phase
IN STOCK - Ready to Ship
The Cummins C200D6D Protects What Matters Most
Keep your business running when the power goes out. The Cummins C200D6D diesel generator safeguards your operations, inventory, productivity, and profitability with reliable backup power you can count on.
Complete Power Solution
This 200kW diesel generator is a fully integrated standby power system designed for commercial applications. It arrives ready to install with a weather-resistant Level 1 aluminum sound enclosure and integrated 24-hour fuel tank. Certified to meet U.S. EPA Tier 3, UL 2200, and NFPA 110 Type 10 standards, this generator delivers proven performance when your business needs it most.
Built for Reliability
Heavy-Duty Cummins EngineAt the heart of this generator is a rugged 6.7-liter inline 6-cylinder diesel engine with a cast iron block. This liquid-cooled, 4-cycle industrial engine runs at 1800 RPM for exceptionally quiet operation and long-lasting durability. It responds quickly to load changes while maintaining low emissions, providing dependable power year after year.
High-Performance AlternatorThe brushless alternator features low reactance 2/3 pitch windings that excel at starting motors and handling demanding electrical loads. It produces clean power with minimal waveform distortion, even with sensitive electronics and nonlinear loads, and offers robust fault-clearing capability during short-circuit conditions.
Intelligent Control SystemThe PowerCommand 1.1 electronic control system manages every aspect of generator operation. It automatically starts and stops the unit, precisely regulates frequency and voltage, displays system status and alarms, provides output metering, and shuts down safely if faults are detected. The system meets NFPA 110 Level 1 compliance requirements for critical applications.
Weather-Resistant EnclosureThe green aluminum sound-attenuated enclosure is engineered to withstand 180 mph wind loads per ASCE 7-10 standards while reducing operational noise. It protects internal components from the elements while maintaining accessibility for routine maintenance.
Integrated Fuel SystemThe 351 gallon dual-wall subbase fuel tank provides 24 hours of runtime at full load and is UL 142 and ULC-S601 listed for safety and compliance.
Regional Fuel Tank Standard Features:
UL 142 and ULC-S601 listed - Minimum 110% secondary IBC 2012 and 2015 certified - All optional features are seismically certified with this range of tanks and generator sets. Requires factory-installed 2 ft vent extensions or higher.
UL 142 & ULC-S601 listed - Minimum 125% secondary containment capacity. NFPA & IFC - Capable of meeting NFPA 30, NFPA 110, and IFC codes with available factory-installed optional features.
Emergency pressure relief vents - Ensure adequate ventilation of the primary and secondary tank compartments under extreme temperature and emergency conditions.
Normal atmospheric vent - Mushroom style vent ensures adequate venting of the primary tank during fill, generator set running, and temperature variations. Raised above fuel fill.
Raised fuel fill - Includes lockable sealed fuel cap. Lifting eyes - Allow lifting of fuel tank with generator set installed.
Certifications & Standards
This generator meets rigorous industry standards including U.S. EPA Tier 3 emissions, UL 2200 safety, NFPA 110 Type 10, ISO 1001, and International Building Code (IBC) Seismic 2012. It is NFPA Type 1 capable for critical backup power applications.
Warranty & Support
Includes a comprehensive 2-year or 1,000-hour standby warranty. Extended warranty options are available upon request.
Specifications
Power Output: 200kW at 120/208V 3-Phase
Model: C200D6D
Fuel: Diesel
Fuel Tank Capacity: 351 gallons
Enclosure: Level 1 Sound Attenuated
Control System: PowerCommand 1.1
Remote Monitoring: Available with optional accessory equipment
Automatic Transfer Switch: Not included. See Cummins OTEC Series Switches
Weight (with fuel tank): 5,112 lbs
Dimensions (with fuel tank): 180"L x 40"W x 93"H
Certifications: EPA Tier 3, UL 2200, NFPA 110 Type 10, ISO 1001, IBC Seismic 2012
DOWNLOADS:
Spec Sheet - C200D6D
Ready to Secure Your Power?
Contact Buckeye Power Systems today to discuss transfer switch options, shipping, and how this generator can protect your business operations.
RELATED C200D6D Generator:
Cummins C200D6D - 200kW @ 277/480V 3-Phase
Get Your Price from Buckeye Power Systems!
Buyers Who Viewed This Listing Also Viewed …
JUST ADDED!
200 kW Cummins #C200D6D, diesel generator set, QSB7-G5-NR3 engine, 324 HP, Tier 3, PMG, sound attenuated enclosure level 2, 0 hours, 2026
Category: Diesel Generators
Seller: McKain Power Systems Consulting LLC
Location: Katy, TX
Mfr: Cummins
Model: C200D6D
Year: 2026
JUST ADDED!
200 KW Cummins #C200D6D, diesel generator set, 120/208 Volts, 324 HP @ 1800 RPM, QSB7-G5 NR3 engine, EPA Tier 3, sound attenuated enclosure, 520 gal. sub-base fuel tank, new
Category: Diesel Generators
Seller: Central States Diesel Generators LLC
Location: Waukesha, WI
Mfr: Cummins
Model: C200D6D
*****ETA Aug 31, 2026***** New Cummins 200 kW standby (180 kW prime) diesel generator set, model C200D6D. Cummins QSB7-G5 NR3 engine rated 324 HP at 1800 RPM, EPA Tier 3 emissions. 3/60/120/208V, 12 lead reconnectable to 480V and other voltages. 200-600 Amp 100% rated main-line circuit breaker. PMG permanent magnet ...more
200 KW Cummins #C200D6D, diesel generator set, 277/480 Volts, 3-phase, 324 HP @ 1800 RPM, QSB7-G5 NR3 engine, Tier 3, sound attenuated enclosure, 2024, new
Category: Diesel Generators
Seller: DEPCO Power Systems
Location: Houston, TX
Mfr: Cummins
Model: C200D6D
Year: 2024
Generator Set Type: Stand-By Engine Model: QSB7-G5 NR3 Fuel Type: Diesel Voltage: 277/480 Model: C200D6D Panel: with Autostart and Safety Shutdowns Frequency: 60 Cycles/Hz Phase: Three Phase, Notes,. Cummins 2 Yr 1000 Hr limited warranty. EPA Stationary Emergency rated for Standby use only.PowerCommand 1.1 digital ...more
200 KW Caterpillar #D200GC, Diesel Generator Set, Sound Attenuated Enclosure, 4364 HP @ 1800 RPM CAT C7.1 Engine, 120/208 Volts, 2022, New Surplus
Category: Diesel Generators
Seller: Diesel-Powered.com
Location: East Earl, PA
Mfr: Caterpillar
Model: C7.1
Year: 2022
Stock#: IE200-289-CT Fuel: Diesel Year: 2022 Voltage: 120/208 Volts Hours: 0 Hours Phase: 1/3 Phase Make: CAT Model: D200GC Serial: CAT0D200CT9W00352 Hertz: 60 Hz Wires: 12 Lead Kilo Watts: 200 kW Mounted: Skid Mounted Fuel Tank: Base Fuel Tank Enclosure: Sound Attenuated Enclosed: Enclosed Lead: Reconnectable Length: ...more
200 KW Olympian #D200P4, diesel generator, weatherproof enclosure, 120/208 Volts, 706.9 hours
Category: Diesel Generators
Seller: Woodstock Power Co
Location: Bala Cynwyd, PA
Mfr: Olympian
Model: D200P4
Year: 2001
Used 200 kW Olympian D200P4 Diesel Generator, Weatherproof enclosure, 800 amp ABB SACE6 breaker, 4001E controller, 900 gallon diesel base tank, Voltage 120/208V Manufacturer Olympian Fuel Type Diesel Hours 706.9.