23 Results
Featured
Howden, turbine generator
Global Equipment International | Chalfont, PA
Category: Steam W/Out Generator Turbines
Seller: Global Equipment International
Location: Chalfont, PA
Mfr: Howden
Howden TWIN Condensing Steam Turbine with A.C. Generator MFG 2018, OEM: Siemens Turbomachinery Equipment Series SST-110, Unit type: Twin-CA 56, Power output: 6.7MW, Main Steam Temp: 445C, Operates on 900F superheated steam at 800psi., Provides plant process steam at 375F at 46psi, RO make-up water treatment system ...more
Featured
Shi-Nippon, 8.0 Mw - Steam turbine - ABB altenrator, 2018
Kraft Power Corp | Pompton Plains, NJ
Category: Steam W/Out Generator Turbines
Seller: Kraft Power Corp
Location: Pompton Plains, NJ
Mfr: Shi Nippon
Year: 2018
KPC have for sale., 8.0 MW – Steam Turbine Generator, New – Never used – surplus., Shin-Nippon– ABB, 8.0 MW – 60 hz, 13.8 KV, - Speed – 7800 / 1800 rpm, Inlet Pressure – 32 Bar A = 465 psig, Temperature – 342 Deg. C. = 647.6 Def. F., Exhaust Steam Pressure – 0.12 ...more
75 HP Terry /SA 520, 185 psig inlet, 3728 RPM, saturated, 65 psig exhaust, CC
Wabash Power Equipment Co | Wheeling, IL
Category: Steam W/Out Generator Turbines
Seller: Wabash Power Equipment Co
Location: Wheeling, IL
Mfr: Terry
More Info, (One) 75HP Terry Steam Turbine Type SA520, 185 psig @ 150F with 65# B.P. exhaust, 3018-3728 RPM. C.C. rotation from governor end. This is a gas expander but could be operated as a turbine. Manufactured in 1984. Identified by: S/N T42681A.
147 HP Terry /GS, 300 psig inlet, 3600 RPM, saturated, 25 psig exhaust, CW
Wabash Power Equipment Co | Wheeling, IL
Category: Steam W/Out Generator Turbines
Seller: Wabash Power Equipment Co
Location: Wheeling, IL
Mfr: Terry
200 HP Terry, non-cond., 600 psi inlet, 4 psig exh., 3550 RPM
Wabash Power Equipment Co | Wheeling, IL
Category: Steam W/Out Generator Turbines
Seller: Wabash Power Equipment Co
Location: Wheeling, IL
Mfr: Terry
250 HP General Electric / 7THRY, 175/400 psig inlet, 3560 RPM, 20 psig exh., 377/750° , CCW
Wabash Power Equipment Co | Wheeling, IL
Category: Steam W/Out Generator Turbines
Seller: Wabash Power Equipment Co
Location: Wheeling, IL
Mfr: General Electric
300 HP General Electric / D-5851-1, 200 psig inlet, 1800 RPM, 10 psig exh., saturated, CW
Wabash Power Equipment Co | Wheeling, IL
Category: Steam W/Out Generator Turbines
Seller: Wabash Power Equipment Co
Location: Wheeling, IL
Mfr: General Electric
Get email updates for newly added Steam W/Out Generator Turbines
Steam Turbines Without Generators (also known as mechanical drive steam turbines or standalone steam turbines) are turbines that use steam to produce mechanical energy, typically for driving equipment like pumps, compressors, or fans. Commonly used in industries like chemical processing, power generation, and oil and gas, these turbines provide efficient, reliable mechanical power for heavy-duty industrial applications.
539 HP Turbodyne, Frame 504HSWK, 850G psi inl, 750°F , 3600rpm, 50G psi ex, 535°F , CW
Fox Innovation & Technologies | LaPorte, TX
Category: Steam W/Out Generator Turbines
Seller: Fox Innovation & Technologies
Location: LaPorte, TX
Mfr: Turbodyne
800 HP Coppus Lufkin, non-condensing, 544 psig @ 504°F, 55# BP exch., 3558 RPM, 47-55 Exhaust Pressure
Wabash Power Equipment Co | Wheeling, IL
Category: Steam W/Out Generator Turbines
Seller: Wabash Power Equipment Co
Location: Wheeling, IL
Mfr: Coppus
1300 HP Terry / CS1, 850 psig inlet, 3560 RPM, 150 psig exhaust, 900° , CW
Wabash Power Equipment Co | Wheeling, IL
Category: Steam W/Out Generator Turbines
Seller: Wabash Power Equipment Co
Location: Wheeling, IL
Mfr: Terry
1314 HP Terry / GABS, 150 psig inlet, 3800 RPM, 15 psig exhaust, 900°, CCW
Wabash Power Equipment Co | Wheeling, IL
Category: Steam W/Out Generator Turbines
Seller: Wabash Power Equipment Co
Location: Wheeling, IL
Mfr: Terry
1718 HP Elliott BYR HP GPL III, Non Condensing, 700 psig @ 750°F, 6258 RPM, Woodward Governor, 2017
Surplus Asset Holdings Inc | Galion, OH
Category: Steam W/Out Generator Turbines
Seller: Surplus Asset Holdings Inc
Location: Galion, OH
Mfr: Elliott
Year: 2017
Clean unit, just removed from mill that has closed. Unit has Govenor, oil pump, manual ready to work.
1800 HP Murray / 142UV2, 250 psig inlet, 3600 RPM, 15 psig exhaust, 500° , CCW
Wabash Power Equipment Co | Wheeling, IL
Category: Steam W/Out Generator Turbines
Seller: Wabash Power Equipment Co
Location: Wheeling, IL
Mfr: Murray
2000 HP Hayward-Tyler / TN24, 1000 psig inlet, 3560 RPM, 100 psig exhaust, 546°, CW
Wabash Power Equipment Co | Wheeling, IL
Category: Steam W/Out Generator Turbines
Seller: Wabash Power Equipment Co
Location: Wheeling, IL
Mfr: Hayward-Tyler
More Info, One (1) New Hayward Tyler Steam Turbine, Type TN24, 1000 psig initial pressure, 546F, with 100 psig B.P. exhaust, CW rotation from governor end, 3560 RPM.
2013 HP Elliott #SBPG-4, 10575 RPM, CCW, 150 psig inlet, 416°F , " vac, 6" inlet down exhaust
Fox Innovation & Technologies | LaPorte, TX
Category: Steam W/Out Generator Turbines
Seller: Fox Innovation & Technologies
Location: LaPorte, TX
Mfr: Elliott
2220 HP Murray / R type, 545 psig inlet, 3600 RPM, 15/65 psig exhaust, 610° , CCW
Wabash Power Equipment Co | Wheeling, IL
Category: Steam W/Out Generator Turbines
Seller: Wabash Power Equipment Co
Location: Wheeling, IL
Mfr: Murray
Steam Turbine Type: Without Generator, More Info, 1 (One) reconditioned 2200 HP Murray Non-Condensing Steam Turbine, Type R, Frame R-2-J, Initial 545 psig @ 610 TTF, exhaust 13 psig, inlet 6", exhaust 12", 1-stage, CCW rotation from governor end, 3600 RPM, manufactured in 1965. Described per the enclosed data sheet.
2420 HP Elliott / RV6, 350 psig inlet, 9550 RPM, 4" HGS, 610°, CCW
Wabash Power Equipment Co | Wheeling, IL
Category: Steam W/Out Generator Turbines
Seller: Wabash Power Equipment Co
Location: Wheeling, IL
Mfr: Elliott
More Info, One (1) 2420HP Elliott condensing, extraction, 6 stage, Type RV-6, Built in 1958. Serial Number U-4307 Initial steam conditions are 350 PSIG at 610F with 4" HG abs, 9550 RPM. Direction of rotations viewed from governor end is counter clockwise. SHIPPING WEIGHT: 24,000 Lbs.
2800 HP Murray / 142UV2, 395 psig inlet, 4670 RPM, 45 psig exhaust, 700°, CCW
Wabash Power Equipment Co | Wheeling, IL
Category: Steam W/Out Generator Turbines
Seller: Wabash Power Equipment Co
Location: Wheeling, IL
Mfr: Murray
More Info, 1 (One) reconditioned 2800 HP Murray non-condensing steam turbine, model 142UV2, 3-stage (composed of (1) Curtis, and (2) Rateau stages). Carbon steel case construction. 395 psig @ 700F, with 45# BP exhaust. 5" inlet (left side) rated at 600 psi 18" exhaust (top) rated at 150 psi Direction of rotation from ...more
3800 HP General Electric #DRV825, Frame 5,4860rpm, 540G psi inlet, 700°F , 24" up exhaust 6" inlet, CCW
Fox Innovation & Technologies | LaPorte, TX
Category: Steam W/Out Generator Turbines
Seller: Fox Innovation & Technologies
Location: LaPorte, TX
Mfr: General Electric
Electric Steam Turbine Starter and Helper originally on a frame 5, Model DRV 825, Speed 4860, Rated 3800 HP, 24" up exhaust flange rating 125#, 6" right hand inlet rated 600#, PGPL Governor, Steam Conditions, 540 gauge inlet, 700 F, 4" exhaust, Serial# 122459, Rotation from gov end CCW, Unit comes with complete spare ...more
6183 HP Murray #RD-4, 3955 RPM, CCW rotation, 570/720/200,10" inlet, up exhaust
Fox Innovation & Technologies | LaPorte, TX
Category: Steam W/Out Generator Turbines
Seller: Fox Innovation & Technologies
Location: LaPorte, TX
Mfr: Murray
7400 HP Worthington #4S, 6000 RPM, 615/720/110, CCW, spare rotor
Fox Innovation & Technologies | LaPorte, TX
Category: Steam W/Out Generator Turbines
Seller: Fox Innovation & Technologies
Location: LaPorte, TX
Mfr: Worthington
8765 HP Elliott #SRV4-3, 8300 RPM, CW rotation, 600/750/145,8" inlet, 12" up exhaust
Fox Innovation & Technologies | LaPorte, TX
Category: Steam W/Out Generator Turbines
Seller: Fox Innovation & Technologies
Location: LaPorte, TX
Mfr: Elliott
9495 HP Dresser / 5QT, 400 psig inlet, 8000 RPM, 2.5" HGS, 720°, CW
Wabash Power Equipment Co | Wheeling, IL
Category: Steam W/Out Generator Turbines
Seller: Wabash Power Equipment Co
Location: Wheeling, IL
Mfr: Dresser
New / Unused 9495 HP (7100KW) Dresser-Rand (Terry) condensing steam turbine, 400 psig @ 720 deg. F, with 2.5" HG ABS, 63,863#/Hr exhaust., S/N D-1691, S.O. U-25181, Model 5QT, multi-stage, multi-valve., Max throttle flow 80,637#/Hr, 8000 RPM., Woodward 505 electrical governor., 8" inlet at 600#, 48" rectangular outlet ...more
Howden, turbine generator
Global Equipment International | Chalfont, PA
Category: Steam W/Out Generator Turbines
Seller: Global Equipment International
Location: Chalfont, PA
Mfr: Howden
Howden TWIN Condensing Steam Turbine with A.C. Generator MFG 2018, OEM: Siemens Turbomachinery Equipment Series SST-110, Unit type: Twin-CA 56, Power output: 6.7MW, Main Steam Temp: 445C, Operates on 900F superheated steam at 800psi., Provides plant process steam at 375F at 46psi, RO make-up water treatment system ...more
Shi-Nippon, 8.0 Mw - Steam turbine - ABB altenrator, 2018
Kraft Power Corp | Pompton Plains, NJ
Category: Steam W/Out Generator Turbines
Seller: Kraft Power Corp
Location: Pompton Plains, NJ
Mfr: Shi Nippon
Year: 2018
KPC have for sale., 8.0 MW – Steam Turbine Generator, New – Never used – surplus., Shin-Nippon– ABB, 8.0 MW – 60 hz, 13.8 KV, - Speed – 7800 / 1800 rpm, Inlet Pressure – 32 Bar A = 465 psig, Temperature – 342 Deg. C. = 647.6 Def. F., Exhaust Steam Pressure – 0.12 ...more