Advanced Search
Surplus Record logo

COOLANT FILTERING SYSTEMS (Also See Filtration Systems)

Cooljet #70-36V, high pressure coolant sys, coolant 3515LVP2, discharge 1000 psi, '05

Request a Quote
Share
Photo Unavailable

Image unavailable Image unavailable Image unavailable Image unavailable Image unavailable Image unavailable

General Specifications


Manufacturer: Cooljet
Model: -70-36V
Description: high pressure
Stock #: C5761-10451
Price: Request a Price

Dealer Information


Century Machinery Co
1937 S Santa Fe Ave
Los Angeles, CA 90021-2917

Contact: Leon Dietch
Tel: 213-627-2847
Fax: 213-627-2499
Email: sales@centurymachinery.com

Gold Level Dealer Since 1988
Website: www.centurymachinery.com

View our Equipment Listings

Detailed Product Description


COOLJET HIGH PRESSURE COOLANT SYSTEM 70-36V,
Turning center Model 3515LVP2, Serial Number 50534
Date Mfg June 27, 2005
SPECIFICATIONS:
FLOW RATE 1 – 8 gpm Auto-Adjust, (5 – 30 liters (min)
DISCHARGE PRESSURE maximum 1000 psi (70 bar)
FLOW CONTROL: Automatic variable.
INLET HOSE FITTING 1" NPT
DISCHARGE FITTING 12 JIC 37º, 1 Standard, 2nd Optional
DISCHARGE HOSE 3/4" X 10 foot (per outlet)
FILTERS: Quantity 4 Standard, Rating 10 micron (nom.)
MOTOR DRIVES:
Main 6 hp. (4.4kw) 208-230/460 volts
Total connected Amps 24 amps @ 230 vac 12 AMPS @ 460 vac
FLEXIBLE FEATURES INCLUDE:
M-Code selectable high pressure, Programmable pressure, Automatic pressure dumping at turret index. The high-pressure coolant delivery is variable & automatically controlled to maintain optimum pressure. This allows for “Pump on Demand" which assures that a constant pressure is maintained with varying tooling and coolant requirements.
EQUIPPED WITH;
Filter A & B Drain On/Off Valve. Filter Drain Open / Close Valve.
Pump Oil Level Sight Glass. Discharge Pressure Gage.
Controls: Main Power Disconnect, Reset/Fill Switch, Thermal Alarm, Alarm
Level Light, Alarm Beeper.

Dimensions: 21.7″ F-B x 53″ L-R x 63″ Ht, Approx. wt. 975 lbs.