TRANSFORMERS, THREE PHASE, 60 CYCLE

750 KVA 13800 Delta Pri. 600Y/347 Sec., Unit substation, remanufactured, (2) available

Request a Quote
Share


General Specifications


KVA: 750.0
Pri.V.: 13800V.
Sec.V.: 600 - 347V.
Stock #:
Price: Request a Price

Dealer Information
Mine Power Services Inc
756 Carrier St
Kamloops, BC V2H1G2 Canada

Contact: Jack Goddyn
Tel: 250-571-4703
Email: jack@minepowerservices.com
  
Gold Level Dealer Since 2018
Website: minepowerservices.com/

View our Equipment Listings

Detailed Product Description


General:

•      CSA Certified
•      Test Reports included
•      600V SIS control wiring
•      Warning labels on all covers and doors to indicate voltages and hazards present
•      Control wiring labeled according to electrical drawings and schematics

15kV High Voltage Section:

•      1 ea - 15kV 600A fused load break switch with safety glass viewing window in door. Fused at 50A.
•      3 ea - Ground ball studs for attaching the grounding cluster when performing maintenance or repairs to the HV system
•      1 ea - 120V 250W heater and thermostat in main switch section
•      1 set - Kirk Key interlocks between the main LB switch and the fuse section to prevent access while energized

Transformer Section:

•      Delta Transformers CPTC0750150, 750 Kva, 13,800 Δ - 600Y/347V
•      Taps: 2 ½ and 5% above and below nominal
•      150° Rise, BIL 95kV
•      Neutral Grounding Resistor, IPC 5A Continuous
•      VPE construction
•      Copper windings
•      Anti-vibration pads
•      Transformer compartment isolated from HV, LV and 600V feeder compartments
•      500 VA 600-120V 1 phase control transformer
•      40 VA 600-120V PT for metering

600V Feeder Section:

•      1200A busbar from transformer to distribution breakers
•      3 ea - 800:5 current transformers for protection and metering
•      4 ea - 600V/400A feeder buckets, c/w Cutler Hammer KD3400FS Visi-break circuit breakers with 400A thermal trip units, and Startco SE-105 ground fault/ground check relays. Padlockable for lockout. Other trip unit ratings available on request.
•      3 ea - 600V/200A feeder buckets, c/w Cutler Hammer KD3400FS Visi-break circuit breakers with 200A thermal trip units, and Startco SE-105 ground fault/ground check relays. Padlockable for lockout. Other trip unit ratings available on request.
•      3 ea - 600V/80A feeder buckets, c/w Cutler Hammer KD3225FS Visi-break circuit breakers with 80A thermal trip units, and Startco SE-105 ground fault/ground check relays. Padlockable for lockout. Other trip unit ratings available on request.
•      Feeder section is designed so that feeder circuits may be safely added or removed without requiring the substation to be shut down
•      Separate control power transformer for each outgoing feeder circuit

Lighting Transformer and Panel:

•      1 ea - 3 phase 25 kVA 600-120/208 lighting transformer
•      1 ea - 100A 3 phase 120/208 lighting panel, 18 circuit
•      4 ea - 1P 15A circuit breakers
•      1 ea - 15A GFCI duplex receptacle with weatherproof cover

Protection, Control and Metering:

•      1 ea - Neutral grounding resistor, 5A continuous
•      1 ea - Startco SE-330 NGR monitor, to trip the 15kV load break switch if there is a fault
•      1 ea - Omron E5CN transformer temperature controller, with 1 thermocouple in the center winding of the transformer
•      1 ea - 0-750V voltage panel meter
•      1 ea - 0-800A current panel meter

Enclosure:

•      Type 3R weatherproof construction
•      Separate compartments for HV, LV, transformer, and 600V
•      Ground bus throughout 2″x ¼″
•      Skid mounted
•      Lifting eyes on the top on all 4 corners

Paint and Finish:

•      Interior and exterior main frame and body - Sky White Powdercoat
•      Exterior doors, panels, ventilation louvers - Safety Orange Powdercoat or customer spec
•      Warning labels on all compartment covers and doors